基于闪电位置数据和Voronoi图的风电场闪电活动分析

Yu Wang, Ze Liu, Fengquan Li, Zhe Li, Jian Li, S. Gu
{"title":"基于闪电位置数据和Voronoi图的风电场闪电活动分析","authors":"Yu Wang, Ze Liu, Fengquan Li, Zhe Li, Jian Li, S. Gu","doi":"10.1109/APL57308.2023.10182068","DOIUrl":null,"url":null,"abstract":"Addressing the issue that the mutual shielding effect of several wind turbines is not fully considered in the current techniques of assessing the lightning risk of wind farms. This study suggests a Voronoi diagram-based method for analyzing lightning activity in wind farm with wind turbine clusters. The outcomes of lightning activity analysis using the conventional grid approach and the Voronoi diagram method suggested in this research are contrasted using a wind farm in Yunnan Province of China as an example. It demonstrates that the suggested approach is better suited for determining the lightning risk associated with a single wind turbine. It is capable of performing an analysis of the lightning parameters of a single wind turbine, including the cloud-ground lightning density, positive lightning ratio, median peak current, and average number of lightning return strokes, etc. Additionally, this approach may detect changes in pertinent lightning parameters both before and after the wind farm is set up. Therefore, it is more appropriate to offer technical assistance to wind farms, especially large wind farms, in order to develop specialized lightning protection strategies.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"114 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Lightning Activities in Wind Farm Based on Lightning Location data and Voronoi Diagram\",\"authors\":\"Yu Wang, Ze Liu, Fengquan Li, Zhe Li, Jian Li, S. Gu\",\"doi\":\"10.1109/APL57308.2023.10182068\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Addressing the issue that the mutual shielding effect of several wind turbines is not fully considered in the current techniques of assessing the lightning risk of wind farms. This study suggests a Voronoi diagram-based method for analyzing lightning activity in wind farm with wind turbine clusters. The outcomes of lightning activity analysis using the conventional grid approach and the Voronoi diagram method suggested in this research are contrasted using a wind farm in Yunnan Province of China as an example. It demonstrates that the suggested approach is better suited for determining the lightning risk associated with a single wind turbine. It is capable of performing an analysis of the lightning parameters of a single wind turbine, including the cloud-ground lightning density, positive lightning ratio, median peak current, and average number of lightning return strokes, etc. Additionally, this approach may detect changes in pertinent lightning parameters both before and after the wind farm is set up. Therefore, it is more appropriate to offer technical assistance to wind farms, especially large wind farms, in order to develop specialized lightning protection strategies.\",\"PeriodicalId\":371726,\"journal\":{\"name\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"volume\":\"114 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APL57308.2023.10182068\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10182068","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

解决当前风电场雷电风险评估技术中未充分考虑多个风力涡轮机相互屏蔽效应的问题。本研究提出了一种基于Voronoi图的方法来分析风力涡轮机集群风电场的闪电活动。以云南某风电场为例,对比了传统网格法和Voronoi图法的闪电活动分析结果。它表明,建议的方法更适合于确定与单个风力涡轮机相关的雷击风险。能够对单个风力发电机的闪电参数进行分析,包括云地闪电密度、正闪电比、中位峰值电流、平均闪电回击次数等。此外,该方法还可以检测到风电场建立前后相关闪电参数的变化。因此,为风电场特别是大型风电场提供技术援助,以制定专门的防雷策略更为合适。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of Lightning Activities in Wind Farm Based on Lightning Location data and Voronoi Diagram
Addressing the issue that the mutual shielding effect of several wind turbines is not fully considered in the current techniques of assessing the lightning risk of wind farms. This study suggests a Voronoi diagram-based method for analyzing lightning activity in wind farm with wind turbine clusters. The outcomes of lightning activity analysis using the conventional grid approach and the Voronoi diagram method suggested in this research are contrasted using a wind farm in Yunnan Province of China as an example. It demonstrates that the suggested approach is better suited for determining the lightning risk associated with a single wind turbine. It is capable of performing an analysis of the lightning parameters of a single wind turbine, including the cloud-ground lightning density, positive lightning ratio, median peak current, and average number of lightning return strokes, etc. Additionally, this approach may detect changes in pertinent lightning parameters both before and after the wind farm is set up. Therefore, it is more appropriate to offer technical assistance to wind farms, especially large wind farms, in order to develop specialized lightning protection strategies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of cost-effective lightning protection measures for underprivileged communities Preliminary Results of Corona Discharge Current Measurements in the Early Formation of Lightning on Tower Performance of Bentonite and Peat Moss Mixtures as Grounding Enhancement Materials Thunderstorm Prediction Model Using SMOTE Sampling and Machine Learning Approach A Year of Global Lightning Deaths and Injuries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1