Ö. Usta, Fatih Ozveren, B. Kara, Cenk Gocer, Halit Mustafa Ozgur
{"title":"一种保护有源配电网不对称故障的定向继电保护新方案","authors":"Ö. Usta, Fatih Ozveren, B. Kara, Cenk Gocer, Halit Mustafa Ozgur","doi":"10.1109/ISGTEurope.2018.8571449","DOIUrl":null,"url":null,"abstract":"This paper presents a new directional protection scheme to provide protection against asymmetrical fault and over unbalance operating conditions. The proposed scheme detects the fault by monitoring the degree of system unbalance using the magnitude of negative sequence reactive power, and discriminates the fault using the direction of negative sequence reactive power. Computer simulation studies have shown that the proposed protection scheme detects the unbalanced fault at buses and produces high speed trip for all lines connected to the buses. When there is a fault within the line, the protecting scheme produces trip signals for CBs at each end of the line, and provides high speed protection if the communication facility is available. When the communication link is not available, a backup protection can be provided for the line.","PeriodicalId":302863,"journal":{"name":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A New Directional Relaying Scheme for the Protection of Active Distribution Networks Against Asymmetric Faults\",\"authors\":\"Ö. Usta, Fatih Ozveren, B. Kara, Cenk Gocer, Halit Mustafa Ozgur\",\"doi\":\"10.1109/ISGTEurope.2018.8571449\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a new directional protection scheme to provide protection against asymmetrical fault and over unbalance operating conditions. The proposed scheme detects the fault by monitoring the degree of system unbalance using the magnitude of negative sequence reactive power, and discriminates the fault using the direction of negative sequence reactive power. Computer simulation studies have shown that the proposed protection scheme detects the unbalanced fault at buses and produces high speed trip for all lines connected to the buses. When there is a fault within the line, the protecting scheme produces trip signals for CBs at each end of the line, and provides high speed protection if the communication facility is available. When the communication link is not available, a backup protection can be provided for the line.\",\"PeriodicalId\":302863,\"journal\":{\"name\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2018.8571449\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2018.8571449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A New Directional Relaying Scheme for the Protection of Active Distribution Networks Against Asymmetric Faults
This paper presents a new directional protection scheme to provide protection against asymmetrical fault and over unbalance operating conditions. The proposed scheme detects the fault by monitoring the degree of system unbalance using the magnitude of negative sequence reactive power, and discriminates the fault using the direction of negative sequence reactive power. Computer simulation studies have shown that the proposed protection scheme detects the unbalanced fault at buses and produces high speed trip for all lines connected to the buses. When there is a fault within the line, the protecting scheme produces trip signals for CBs at each end of the line, and provides high speed protection if the communication facility is available. When the communication link is not available, a backup protection can be provided for the line.