{"title":"四轨轻轨系统绝缘轨架和车站避雷器的间接雷击浪涌分析","authors":"F. A. Rahman, U. Amirulddin, M. Kadir, M. Osman","doi":"10.1109/APL57308.2023.10181709","DOIUrl":null,"url":null,"abstract":"This paper presents a study comparing the performance of a fourth rail direct current (DC) urban transit system when affected by an indirect lightning strike. Two different designs were used: one with a Cast Epoxy (CE) bracket equipped with a 3EB4-010 arrester, and the other with a Glass Reinforced Plastic (GRP) bracket equipped with a PDTA09 arrester. To replicate the indirect lightning strike, a lightning induced overvoltage was generated using the Rusck model. The model utilized the sum of two Heidler functions as the input for the lightning channel base current, assuming a perfectly conducting ground. The objective of this study is to determine whether an indirect lightning strike has any impact on the performance of the insulated rail bracket and station arrester of the LRT Kelana Jaya line, considering their different materials and residual voltage limits, respectively. Simulations were conducted using the Electromagnetic Transients Program - Restructured Version (EMTP-RV), and the performance of the two designs was compared when subjected to a 30 kA $(5/ 80 \\mu \\mathrm{s})$ induced current. The results showed that the GRP bracket, which has a higher permittivity, performed better when paired with the PDTA09 arrester, which has a lower residual voltage limit. This combination resulted in slightly lower induced overvoltage and significantly lower residual voltage being clamped by the station arrester.","PeriodicalId":371726,"journal":{"name":"2023 12th Asia-Pacific International Conference on Lightning (APL)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Indirect Lightning Surge Analysis of Insulated Rail Bracket and Station Arrester in a Fourth Rail LRT System\",\"authors\":\"F. A. Rahman, U. Amirulddin, M. Kadir, M. Osman\",\"doi\":\"10.1109/APL57308.2023.10181709\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a study comparing the performance of a fourth rail direct current (DC) urban transit system when affected by an indirect lightning strike. Two different designs were used: one with a Cast Epoxy (CE) bracket equipped with a 3EB4-010 arrester, and the other with a Glass Reinforced Plastic (GRP) bracket equipped with a PDTA09 arrester. To replicate the indirect lightning strike, a lightning induced overvoltage was generated using the Rusck model. The model utilized the sum of two Heidler functions as the input for the lightning channel base current, assuming a perfectly conducting ground. The objective of this study is to determine whether an indirect lightning strike has any impact on the performance of the insulated rail bracket and station arrester of the LRT Kelana Jaya line, considering their different materials and residual voltage limits, respectively. Simulations were conducted using the Electromagnetic Transients Program - Restructured Version (EMTP-RV), and the performance of the two designs was compared when subjected to a 30 kA $(5/ 80 \\\\mu \\\\mathrm{s})$ induced current. The results showed that the GRP bracket, which has a higher permittivity, performed better when paired with the PDTA09 arrester, which has a lower residual voltage limit. This combination resulted in slightly lower induced overvoltage and significantly lower residual voltage being clamped by the station arrester.\",\"PeriodicalId\":371726,\"journal\":{\"name\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 12th Asia-Pacific International Conference on Lightning (APL)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APL57308.2023.10181709\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 12th Asia-Pacific International Conference on Lightning (APL)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APL57308.2023.10181709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本文介绍了一项比较四轨直流(DC)城市交通系统在受间接雷击影响时的性能的研究。使用了两种不同的设计:一种是带有3EB4-010避雷器的铸环氧树脂(CE)支架,另一种是带有PDTA09避雷器的玻璃钢(GRP)支架。为了复制间接雷击,使用Rusck模型产生了雷致过电压。该模型采用两个Heidler函数的和作为雷电通道基极电流的输入,假设有完美导电的地。本研究的目的是确定间接雷击是否会对轻型轻轨Kelana Jaya线的绝缘轨道支架和车站避雷器的性能产生影响,分别考虑它们的不同材料和残余电压限值。利用电磁瞬变程序重构版(EMTP-RV)进行了仿真,并比较了两种设计在30 kA $(5/ 80 \mu \ mathm {s})$感应电流下的性能。结果表明,具有较高介电常数的GRP支架与具有较低残余电压极限的PDTA09避雷器配对时性能更好。这种组合导致了稍低的感应过电压和明显较低的剩余电压被车站避雷器箝制。
Indirect Lightning Surge Analysis of Insulated Rail Bracket and Station Arrester in a Fourth Rail LRT System
This paper presents a study comparing the performance of a fourth rail direct current (DC) urban transit system when affected by an indirect lightning strike. Two different designs were used: one with a Cast Epoxy (CE) bracket equipped with a 3EB4-010 arrester, and the other with a Glass Reinforced Plastic (GRP) bracket equipped with a PDTA09 arrester. To replicate the indirect lightning strike, a lightning induced overvoltage was generated using the Rusck model. The model utilized the sum of two Heidler functions as the input for the lightning channel base current, assuming a perfectly conducting ground. The objective of this study is to determine whether an indirect lightning strike has any impact on the performance of the insulated rail bracket and station arrester of the LRT Kelana Jaya line, considering their different materials and residual voltage limits, respectively. Simulations were conducted using the Electromagnetic Transients Program - Restructured Version (EMTP-RV), and the performance of the two designs was compared when subjected to a 30 kA $(5/ 80 \mu \mathrm{s})$ induced current. The results showed that the GRP bracket, which has a higher permittivity, performed better when paired with the PDTA09 arrester, which has a lower residual voltage limit. This combination resulted in slightly lower induced overvoltage and significantly lower residual voltage being clamped by the station arrester.