{"title":"不同环境压力条件下飞机导线上故障电弧的传播","authors":"Yongxing Wang, D. Koenig, F. Hoertz, T. Fugels","doi":"10.1109/DEIV.2004.1422712","DOIUrl":null,"url":null,"abstract":"Fault ares occurred in damageo wires have been identified as a failure reason for many aircraft accidents. As there are hundreds of kilometers of wiring in a commercial aircraft, the damaged wires are extremely difficult to be detected at aircraft maintenance. Thus more attention on the performance of applied wire insulation in aircraft in the stage of development of the wire insulation is necessary. To cope with the fault type \"arc failure\" and in order to increase the aircraft safety, various of arc resistance test methods have been developed by different organisations in the last years. But all of them have not taken into account the environmental conditions in an aircraft. Therefore a new test method considering the environmental pressure conditions has been developed. According to this new method, more than 300 fault are tests have-been performed with typical aircraft wire insulations under different environmental conditions. The test results show that the environmental conditions have an important influence on the fault arc behaviour. The detailed test results are presented and discussed in this paper.","PeriodicalId":137370,"journal":{"name":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Fault arc propagation on aircraft wires under different environmental pressure conditions\",\"authors\":\"Yongxing Wang, D. Koenig, F. Hoertz, T. Fugels\",\"doi\":\"10.1109/DEIV.2004.1422712\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fault ares occurred in damageo wires have been identified as a failure reason for many aircraft accidents. As there are hundreds of kilometers of wiring in a commercial aircraft, the damaged wires are extremely difficult to be detected at aircraft maintenance. Thus more attention on the performance of applied wire insulation in aircraft in the stage of development of the wire insulation is necessary. To cope with the fault type \\\"arc failure\\\" and in order to increase the aircraft safety, various of arc resistance test methods have been developed by different organisations in the last years. But all of them have not taken into account the environmental conditions in an aircraft. Therefore a new test method considering the environmental pressure conditions has been developed. According to this new method, more than 300 fault are tests have-been performed with typical aircraft wire insulations under different environmental conditions. The test results show that the environmental conditions have an important influence on the fault arc behaviour. The detailed test results are presented and discussed in this paper.\",\"PeriodicalId\":137370,\"journal\":{\"name\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DEIV.2004.1422712\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"XXIst International Symposium on Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2004.1422712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

发生在损坏导线上的故障区域已被确定为许多飞机事故的故障原因。由于商用飞机的电线长达数百公里,因此在飞机维修时很难发现损坏的电线。因此,在飞机用绝缘电线的发展阶段,对其性能给予更多的关注是必要的。为了应对“电弧失效”的故障类型,提高飞机的安全性,近年来不同机构开发了各种抗电弧试验方法。但所有这些都没有考虑到飞机的环境条件。为此,提出了一种考虑环境压力条件的试验方法。根据该方法,对典型飞机电线绝缘在不同环境条件下进行了300多次故障试验。试验结果表明,环境条件对故障电弧的行为有重要影响。本文给出了详细的试验结果并进行了讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fault arc propagation on aircraft wires under different environmental pressure conditions
Fault ares occurred in damageo wires have been identified as a failure reason for many aircraft accidents. As there are hundreds of kilometers of wiring in a commercial aircraft, the damaged wires are extremely difficult to be detected at aircraft maintenance. Thus more attention on the performance of applied wire insulation in aircraft in the stage of development of the wire insulation is necessary. To cope with the fault type "arc failure" and in order to increase the aircraft safety, various of arc resistance test methods have been developed by different organisations in the last years. But all of them have not taken into account the environmental conditions in an aircraft. Therefore a new test method considering the environmental pressure conditions has been developed. According to this new method, more than 300 fault are tests have-been performed with typical aircraft wire insulations under different environmental conditions. The test results show that the environmental conditions have an important influence on the fault arc behaviour. The detailed test results are presented and discussed in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
期刊最新文献
Effect of pressure on the behavior of cathode spots in oxide removal by are discharge Flashover voltage of alumina ceramic contaminated by metal vapor in vacuum interrupters Vacuum electrical breakdown characteristics and surface chemical compositions of titanium electrodes with oxidation conditions Measurements of the molybdenum anode temperature in a hot refractory anode vacuum are Emission characteristics of cathodes pressed from icopper nanopowders
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1