畸变电压条件下改进的有源滤波器

F. Hasan, A. R. Beig
{"title":"畸变电压条件下改进的有源滤波器","authors":"F. Hasan, A. R. Beig","doi":"10.1109/APEC.2013.6520756","DOIUrl":null,"url":null,"abstract":"The increasing use of power electronic system has led voltage harmonic distortion level to an unacceptable level at point of common coupling (PCC). Most of the modern solutions of eliminating load current harmonics by using active filter is based on sinusoidal source voltage. However, the voltage at PCC is not purely sinusoisdal. This paper proposes a shunt active filter (SAF) based on instantaneous active and reactive power theory which can mitigate the load harmonics properly even if the source voltage is distorted. Space vector PWM based voltage source inverter is used in current control mode to filter out current harmonics. PI controllers are used for the current controller to get desired dynamic response. The proposed algorithm is verified through simulation. Real life conditions are considered in the simulation and the simulation results are presented.","PeriodicalId":256756,"journal":{"name":"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An improved active filter for distorted voltage conditions\",\"authors\":\"F. Hasan, A. R. Beig\",\"doi\":\"10.1109/APEC.2013.6520756\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The increasing use of power electronic system has led voltage harmonic distortion level to an unacceptable level at point of common coupling (PCC). Most of the modern solutions of eliminating load current harmonics by using active filter is based on sinusoidal source voltage. However, the voltage at PCC is not purely sinusoisdal. This paper proposes a shunt active filter (SAF) based on instantaneous active and reactive power theory which can mitigate the load harmonics properly even if the source voltage is distorted. Space vector PWM based voltage source inverter is used in current control mode to filter out current harmonics. PI controllers are used for the current controller to get desired dynamic response. The proposed algorithm is verified through simulation. Real life conditions are considered in the simulation and the simulation results are presented.\",\"PeriodicalId\":256756,\"journal\":{\"name\":\"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2013.6520756\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2013.6520756","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

随着电力电子系统的日益普及,在共耦合点(PCC)电压谐波失真水平已达到不可接受的水平。现代大多数采用有源滤波器消除负载电流谐波的方法都是基于正弦源电压。然而,PCC的电压并不是纯粹的正弦波。提出了一种基于瞬时有功与无功原理的并联有源滤波器(SAF),该滤波器在电源电压畸变的情况下也能较好地抑制负载谐波。在电流控制模式下,采用空间矢量PWM电压源逆变器滤波电流谐波。电流控制器采用PI控制器,以获得期望的动态响应。通过仿真验证了该算法的有效性。仿真考虑了实际情况,给出了仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An improved active filter for distorted voltage conditions
The increasing use of power electronic system has led voltage harmonic distortion level to an unacceptable level at point of common coupling (PCC). Most of the modern solutions of eliminating load current harmonics by using active filter is based on sinusoidal source voltage. However, the voltage at PCC is not purely sinusoisdal. This paper proposes a shunt active filter (SAF) based on instantaneous active and reactive power theory which can mitigate the load harmonics properly even if the source voltage is distorted. Space vector PWM based voltage source inverter is used in current control mode to filter out current harmonics. PI controllers are used for the current controller to get desired dynamic response. The proposed algorithm is verified through simulation. Real life conditions are considered in the simulation and the simulation results are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An immune-algorithm-based dead-time elimination PWM control strategy in a single-phase inverter Performance analysis of conventional STATCOMs and STATCOMs with energy storage in electric arc furnace applications Six transformer based asymmetrical embedded Z-source inverters Contactless power transfer system for high power piezoelectric actuators in aeronautical applications The Jiles Atherton model for description of hysteresis in lithium battery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1