{"title":"分散发电并网孤岛模式下电流控制器分析","authors":"N. D. Tuyen, G. Fujita","doi":"10.1109/UPEC.2012.6398627","DOIUrl":null,"url":null,"abstract":"An islanding is that the islanded entity including DGs and critical load disconnects from the utility and then, operates in the islanded mode. During that mode, the Power Electronic Interface of DGs not only has a role in keeping the Point of Common Coupling's voltage within a required range, it also needs to make islanded frequency arbitrarily at normal values. This paper investigates the operation response while keeping the conventional current controller in some cases of typical islanded loads and then, validate feasibility of proposed current controller for the islanded entity dealing with transient-to-island mode. The islanding detection method by using negative-sequence impedances also facilitates the fast switching for the entire control scheme. The droop control mechanism is presented for inductive-reductive impedance.","PeriodicalId":326950,"journal":{"name":"2012 47th International Universities Power Engineering Conference (UPEC)","volume":"1960 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analysis of current-controller in grid-connected and islanded mode for dispersed generation\",\"authors\":\"N. D. Tuyen, G. Fujita\",\"doi\":\"10.1109/UPEC.2012.6398627\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An islanding is that the islanded entity including DGs and critical load disconnects from the utility and then, operates in the islanded mode. During that mode, the Power Electronic Interface of DGs not only has a role in keeping the Point of Common Coupling's voltage within a required range, it also needs to make islanded frequency arbitrarily at normal values. This paper investigates the operation response while keeping the conventional current controller in some cases of typical islanded loads and then, validate feasibility of proposed current controller for the islanded entity dealing with transient-to-island mode. The islanding detection method by using negative-sequence impedances also facilitates the fast switching for the entire control scheme. The droop control mechanism is presented for inductive-reductive impedance.\",\"PeriodicalId\":326950,\"journal\":{\"name\":\"2012 47th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"1960 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 47th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2012.6398627\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 47th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2012.6398627","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of current-controller in grid-connected and islanded mode for dispersed generation
An islanding is that the islanded entity including DGs and critical load disconnects from the utility and then, operates in the islanded mode. During that mode, the Power Electronic Interface of DGs not only has a role in keeping the Point of Common Coupling's voltage within a required range, it also needs to make islanded frequency arbitrarily at normal values. This paper investigates the operation response while keeping the conventional current controller in some cases of typical islanded loads and then, validate feasibility of proposed current controller for the islanded entity dealing with transient-to-island mode. The islanding detection method by using negative-sequence impedances also facilitates the fast switching for the entire control scheme. The droop control mechanism is presented for inductive-reductive impedance.