掌侧锁定钢板治疗桡骨远端骨折的前瞻性研究

{"title":"掌侧锁定钢板治疗桡骨远端骨折的前瞻性研究","authors":"","doi":"10.33140/ijor.03.01.07","DOIUrl":null,"url":null,"abstract":"Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced\nextra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated\nwith manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated\nto restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there\nis still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal\nend radius treated by open reduction and internal fixation using locking compression plating (LCP).\nMethods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital\ntreated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and\nDecember 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by\nGartland and Werley’s combined subjective and objective criteria.\nResults: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and\nstudied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23\ngood results, and 07 fair results during latest follow up.\nConclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the\ndistal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the\nshape and function of the wrist.","PeriodicalId":192630,"journal":{"name":"International Journal of Orthopaedics Research","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Prospective Study on Treatment of Distal Radial Fractures Using Volar Locking\\nPlate\",\"authors\":\"\",\"doi\":\"10.33140/ijor.03.01.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced\\nextra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated\\nwith manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated\\nto restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there\\nis still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal\\nend radius treated by open reduction and internal fixation using locking compression plating (LCP).\\nMethods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital\\ntreated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and\\nDecember 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by\\nGartland and Werley’s combined subjective and objective criteria.\\nResults: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and\\nstudied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23\\ngood results, and 07 fair results during latest follow up.\\nConclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the\\ndistal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the\\nshape and function of the wrist.\",\"PeriodicalId\":192630,\"journal\":{\"name\":\"International Journal of Orthopaedics Research\",\"volume\":\"30 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Orthopaedics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33140/ijor.03.01.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Orthopaedics Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33140/ijor.03.01.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

桡骨远端骨折是骨科最常见的损伤之一。移位性关节外或关节内骨折需要解剖复位才能获得良好的治疗效果。从历史上看,这些骨折是通过手法和铸造治疗的,有或没有克氏针固定。现代电镀技术已被提倡恢复解剖对齐和允许早期活动。尽管有各种各样的治疗选择,但关于治疗这些骨折的最佳方法仍然存在争议。本研究的目的是评估50例桡骨远端骨折经切开复位内固定锁定加压钢板(LCP)治疗。方法:对2018年1月至12月在某三级医院行切开复位内固定锁定加压钢板(LCP)治疗的急性桡骨远端骨折患者50例进行研究。在研究结束时,根据gartland和Werley的主观和客观综合标准,功能结果被评为优秀、良好或差。结果:选取50例符合纳入标准的桡骨远端骨折进行手术研究。10例骨折采用关节外锁定加压t钢板固定,40例骨折采用关节旁锁定加压t钢板固定。根据Gartland和Werley的评分量表,在最近的随访中,20名学生表现优异,23名学生表现良好,07名学生表现一般。结论:尽管样本量很小,随访时间也很短,但桡骨远端掌侧锁定钢板内固定在腕关节形状和功能恢复方面对桡骨远端骨折的治疗有显著改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Prospective Study on Treatment of Distal Radial Fractures Using Volar Locking Plate
Introduction: Distal radius fractures are one of the most common injuries which come to the orthopaedic surgeons. Displaced extra-or intra-articular fractures require anatomical reduction for a good outcome. Historically, these fractures were treated with manipulation and casting, with or without Kirschner (K) wire fixation. Modern plating techniques have been advocated to restore anatomical alignment and allow early mobilisation. Despite the wide variety of treatment options available there is still debate about the best way to treat these fractures. The aim of this study was to evaluate fifty cases of fracture distal end radius treated by open reduction and internal fixation using locking compression plating (LCP). Methods: The present study was carried out on 50 cases of acute fracture distal radius admitted at a tertiary care hospital treated by open reduction and internal fixation using locking compression plating (LCP) between January 2018 and December 2018. Functional results were rated at the end of the study as excellent, good or poor as criteria laid down by Gartland and Werley’s combined subjective and objective criteria. Results: 50 cases of fracture distal radius were selected for study that fulfill the inclusion criteria, were operated and studied. 10 fractures were fixed using Extra-articular Locking Compression T-Plates, 40 fractures were fixed using Juxtaarticular Locking Compression T-Plates. According to the Gartland and Werley’s rating scale, 20 had excellent results, 23 good results, and 07 fair results during latest follow up. Conclusion: Notwithstanding a very small sample size and a short follow up, Volar locking plate osteosynthesis at the distal radius signifies a significant improvement in the treatment of distal radial fractures in terms of restoration of the shape and function of the wrist.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Minimal Brain Dysfunction, Syndrome of Contractures and Deformities, SoCalled Idiopathic Scoliosis, Problem of Hips and Knees-in 12 Points and 12 Figures The Evaluation and Treatment of Patients Referred for Rotator Cuff TearsOur Experience Gene Expression Under Combined Hypoxia And Acidosis In Chondrosarcoma Chronic Wrist Pain Among Handstand Practitioners Core Decompression For Treatment of Avascular Necrosis of Femoral Head In Children With Sickle Cell Anemia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1