{"title":"用于放射性核素功能分子成像的高分辨率和高灵敏度探测器:闪烁体像素大小、光电探测器阳极间距、准直技术和读数的作用","authors":"F. Garibaldi, R. Accorsi, M. Cinti, E. Cisbani, S. Colilli, F. Cusanno, R. Fratoni, F. Giuliani, M. Gricia, R. Lanza, S. Meo, M. Lucentini, S. Majewski, R. Pani, R. Pellegrini, F. Santavenere, B. M. W. Tsui","doi":"10.1109/NSSMIC.2005.1596919","DOIUrl":null,"url":null,"abstract":"Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented","PeriodicalId":105619,"journal":{"name":"IEEE Nuclear Science Symposium Conference Record, 2005","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout\",\"authors\":\"F. Garibaldi, R. Accorsi, M. Cinti, E. Cisbani, S. Colilli, F. Cusanno, R. Fratoni, F. Giuliani, M. Gricia, R. Lanza, S. Meo, M. Lucentini, S. Majewski, R. Pani, R. Pellegrini, F. Santavenere, B. M. W. Tsui\",\"doi\":\"10.1109/NSSMIC.2005.1596919\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented\",\"PeriodicalId\":105619,\"journal\":{\"name\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposium Conference Record, 2005\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2005.1596919\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposium Conference Record, 2005","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2005.1596919","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High resolution and high sensitivity detectors for functional molecular imaging with radionuclides: the role of scintillator pixel size, photodetector anode pitch, collimation technique, and of the readout
Good spatial resolution and high sensitivity are required for detectors to be used for most of the bio-medical research and application (small animal imaging, detection of small tumors). In this paper we report on parameter optimization of single photon gamma rays detectors. Simulations and measurements were performed for designing and building detectors for early detection of small tumors in breast and in small animal imaging. Critical parameters are: contrast and signal to noise ratio (SNR). Intrinsic performances (spatial resolution, pixel identification etc.) were optimized first. Arrays of scintillators (NaI(Tl)) of different pixel pitch (down to the present technological limits for NaI(Tl) arrays fabrication (pitch of 2times2 mm2, 1.5times1.5 mm2 and 1.2times1.2 mm2 )) were coupled to arrays of PSPMTs with two anode readout element dimensions (6times6 mm2 and 3times3 mm2). Detectors having field of view of 100times100 mm2 and 150times200 mm2 were designed and built. An electronics system for reading out all the anode pad signals has been designed and constructed. Finally the collimation technique was considered. The limits of the coded aperture option have been studied. Preliminary results of these studies are presented