大电流、高真空表面放电开关绝缘子的质量侵蚀和表面电压保持恢复

T. Engel, S. L. Wester, M. Kristiansen, L. Hatfield
{"title":"大电流、高真空表面放电开关绝缘子的质量侵蚀和表面电压保持恢复","authors":"T. Engel, S. L. Wester, M. Kristiansen, L. Hatfield","doi":"10.1109/MODSYM.1994.597100","DOIUrl":null,"url":null,"abstract":"A high current discharge across the surface of an insulator in high vacuum is investigated. The mass erosion of the insulator and its surface voltage holdoff recovery are the two most important parameters of this investigation. Typically, the discharge current reaches 350 kA peak with a pulse length of 60 p (i.e., 5 periods of a damped sinusoidal pulse). The vacuum level is maintained at lo6 Torr. The insulator materials tested include a variety of polymeric (i.e., polyethylene, nylon, epoxy-fiberglass composites, and polyurethane) and ceramic (alumina, silicon nitride, and zirconia) insulators. Insulator mass erosion and surface voltage holdoff recovery versus electrode material has also been investigated. The electrode materials used include stainless steel, molybdenum, copper, copper-tungsten, brass, aluminum, and lead. Insulator materials that have low mass erosion and good surface voltage holdoff recovery have potential applications in high power vacuum switches. Breakdown voltage histories and mass erosion data were obtained for the plastics, but only breakdown voltages were obtained for the ceramics.","PeriodicalId":330796,"journal":{"name":"Twenty-First International Power Modulator Symposium, Conference","volume":"80 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mass Erosion And Surface Voltage Holdoff Recovery Of High Current, High Vacuum Surface Discharge Switch Insulators\",\"authors\":\"T. Engel, S. L. Wester, M. Kristiansen, L. Hatfield\",\"doi\":\"10.1109/MODSYM.1994.597100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A high current discharge across the surface of an insulator in high vacuum is investigated. The mass erosion of the insulator and its surface voltage holdoff recovery are the two most important parameters of this investigation. Typically, the discharge current reaches 350 kA peak with a pulse length of 60 p (i.e., 5 periods of a damped sinusoidal pulse). The vacuum level is maintained at lo6 Torr. The insulator materials tested include a variety of polymeric (i.e., polyethylene, nylon, epoxy-fiberglass composites, and polyurethane) and ceramic (alumina, silicon nitride, and zirconia) insulators. Insulator mass erosion and surface voltage holdoff recovery versus electrode material has also been investigated. The electrode materials used include stainless steel, molybdenum, copper, copper-tungsten, brass, aluminum, and lead. Insulator materials that have low mass erosion and good surface voltage holdoff recovery have potential applications in high power vacuum switches. Breakdown voltage histories and mass erosion data were obtained for the plastics, but only breakdown voltages were obtained for the ceramics.\",\"PeriodicalId\":330796,\"journal\":{\"name\":\"Twenty-First International Power Modulator Symposium, Conference\",\"volume\":\"80 4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Twenty-First International Power Modulator Symposium, Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MODSYM.1994.597100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Twenty-First International Power Modulator Symposium, Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MODSYM.1994.597100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了高真空条件下绝缘子表面的大电流放电现象。绝缘子的质量侵蚀和表面电压保持恢复是本研究的两个最重要的参数。通常,放电电流达到350ka峰值,脉冲长度为60p(即5个周期的阻尼正弦脉冲)。真空度保持在lo6托。测试的绝缘体材料包括各种聚合物(即聚乙烯、尼龙、环氧玻璃纤维复合材料和聚氨酯)和陶瓷(氧化铝、氮化硅和氧化锆)绝缘体。还研究了绝缘子质量侵蚀和表面电压保持恢复与电极材料的关系。所用的电极材料包括不锈钢、钼、铜、铜钨、黄铜、铝和铅。具有低质量侵蚀和良好表面电压保持恢复性能的绝缘子材料在大功率真空开关中具有潜在的应用前景。得到了塑料的击穿电压历史和质量侵蚀数据,但只得到了陶瓷的击穿电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mass Erosion And Surface Voltage Holdoff Recovery Of High Current, High Vacuum Surface Discharge Switch Insulators
A high current discharge across the surface of an insulator in high vacuum is investigated. The mass erosion of the insulator and its surface voltage holdoff recovery are the two most important parameters of this investigation. Typically, the discharge current reaches 350 kA peak with a pulse length of 60 p (i.e., 5 periods of a damped sinusoidal pulse). The vacuum level is maintained at lo6 Torr. The insulator materials tested include a variety of polymeric (i.e., polyethylene, nylon, epoxy-fiberglass composites, and polyurethane) and ceramic (alumina, silicon nitride, and zirconia) insulators. Insulator mass erosion and surface voltage holdoff recovery versus electrode material has also been investigated. The electrode materials used include stainless steel, molybdenum, copper, copper-tungsten, brass, aluminum, and lead. Insulator materials that have low mass erosion and good surface voltage holdoff recovery have potential applications in high power vacuum switches. Breakdown voltage histories and mass erosion data were obtained for the plastics, but only breakdown voltages were obtained for the ceramics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fiber-optic Control Of Current Filaments In High Gain Photoconductive Semiconductor Switches Life Time Testing Of High Power Ignitrons Thyratron Design & Circuit Techniques To Overcome The Adverse Effects Of High Inverse Voltages A Theorem On The Dependence Of Hm On Gain In A Magnetic Pulse Compressor, And Its Implications On The Core Volume Formula A Klystron-modulator Interlock And Fault Acquisition System Using G-64, VME, And MIL-1553-B Standards
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1