{"title":"利用延迟线接触模式对陶瓷薄板进行超声研究","authors":"Radostin Kasarov","doi":"10.1109/eeae53789.2022.9831408","DOIUrl":null,"url":null,"abstract":"The aim of this work is to investigate plates of Peltier modules by means of an ultrasonic method. A pulse-echo contact method was applied for precise measurement of thickness. Transducers with delay lines, emitting at 5 MHz, 10 MHz, 15 MHz and 20 MHz, were used to determine the operating frequency range. An analysis of a number of echoes, amplitude and shape of signals, pulse duration and pulse rise time was performed. Ceramic plates of six Peltier modules, models TEC1-12708 and TEC1-12710, were measured with a selected transducer of 15 MHz. Thicknesses at 25 points of each plate were determined. Variation of the obtained values is observed. Comparative analysis of the results for all measured plates can be used for quality evaluation of the modules.","PeriodicalId":441906,"journal":{"name":"2022 8th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultrasonic Investigation of Thin Ceramic Plates by Means of Delay Line Contact Mode\",\"authors\":\"Radostin Kasarov\",\"doi\":\"10.1109/eeae53789.2022.9831408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this work is to investigate plates of Peltier modules by means of an ultrasonic method. A pulse-echo contact method was applied for precise measurement of thickness. Transducers with delay lines, emitting at 5 MHz, 10 MHz, 15 MHz and 20 MHz, were used to determine the operating frequency range. An analysis of a number of echoes, amplitude and shape of signals, pulse duration and pulse rise time was performed. Ceramic plates of six Peltier modules, models TEC1-12708 and TEC1-12710, were measured with a selected transducer of 15 MHz. Thicknesses at 25 points of each plate were determined. Variation of the obtained values is observed. Comparative analysis of the results for all measured plates can be used for quality evaluation of the modules.\",\"PeriodicalId\":441906,\"journal\":{\"name\":\"2022 8th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE)\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 8th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eeae53789.2022.9831408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 8th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eeae53789.2022.9831408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本工作的目的是利用超声方法研究珀尔帖模块的板。采用脉冲回波接触法精确测量厚度。使用带有延迟线的换能器,发射频率分别为5 MHz、10 MHz、15 MHz和20 MHz,以确定工作频率范围。对多个回波、信号幅度和形状、脉冲持续时间和脉冲上升时间进行了分析。选用15mhz的换能器对6个Peltier模块TEC1-12708和TEC1-12710的陶瓷板进行了测量。测定了每块板25个点的厚度。观察所得值的变化。对所有测量板的结果进行对比分析,可用于模块的质量评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasonic Investigation of Thin Ceramic Plates by Means of Delay Line Contact Mode
The aim of this work is to investigate plates of Peltier modules by means of an ultrasonic method. A pulse-echo contact method was applied for precise measurement of thickness. Transducers with delay lines, emitting at 5 MHz, 10 MHz, 15 MHz and 20 MHz, were used to determine the operating frequency range. An analysis of a number of echoes, amplitude and shape of signals, pulse duration and pulse rise time was performed. Ceramic plates of six Peltier modules, models TEC1-12708 and TEC1-12710, were measured with a selected transducer of 15 MHz. Thicknesses at 25 points of each plate were determined. Variation of the obtained values is observed. Comparative analysis of the results for all measured plates can be used for quality evaluation of the modules.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tolerance Analysis of SEPIC DC-DC Converter Investigation Of Braking Deceleration In Vehicle Mathematical Model of Operability of a Single-phase Bridge Rectifier Indoor air measurements for particle pollution Structural–functional model of the students’ adaptation process to the European Credit Transfer System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1