芳纶纤维碾压混凝土梁柱节点性能评价

V. Jayanthi
{"title":"芳纶纤维碾压混凝土梁柱节点性能评价","authors":"V. Jayanthi","doi":"10.21741/9781644901953-2","DOIUrl":null,"url":null,"abstract":"Abstract-In reinforced concrete structure beam, the beam column joints are more crucial zones which are most susceptible to failure during earthquake excitation. It is very important to design the joint to dissipate the large amount of energy to the neighbouring elements without loss of strength and ductility. Several retrofitting methods are employed to strengthen the beam column joint. The effective method one among is Fibre Reinforced Polymer (FRP) composites. In this paper, the deflection of beam column joint wrapped with aramid fibre has been calculated and it is compared with Ansys software solution. From the results, the deflection of the joint is decreased when aramid fibre is used.","PeriodicalId":135346,"journal":{"name":"Sustainable Materials and Smart Practices","volume":"2011 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance Evaluation of RCC Beam Column Joint with Aramid Fibre\",\"authors\":\"V. Jayanthi\",\"doi\":\"10.21741/9781644901953-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract-In reinforced concrete structure beam, the beam column joints are more crucial zones which are most susceptible to failure during earthquake excitation. It is very important to design the joint to dissipate the large amount of energy to the neighbouring elements without loss of strength and ductility. Several retrofitting methods are employed to strengthen the beam column joint. The effective method one among is Fibre Reinforced Polymer (FRP) composites. In this paper, the deflection of beam column joint wrapped with aramid fibre has been calculated and it is compared with Ansys software solution. From the results, the deflection of the joint is decreased when aramid fibre is used.\",\"PeriodicalId\":135346,\"journal\":{\"name\":\"Sustainable Materials and Smart Practices\",\"volume\":\"2011 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sustainable Materials and Smart Practices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21741/9781644901953-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sustainable Materials and Smart Practices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21741/9781644901953-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

摘要在钢筋混凝土结构梁中,梁柱节点是地震作用下最容易发生破坏的关键部位。在不损失强度和延性的情况下,将大量的能量分散到相邻的单元中是非常重要的。采用几种加固方法对梁柱节点进行加固。其中有效的方法之一是纤维增强聚合物(FRP)复合材料。本文对芳纶包绕梁柱节点的挠度进行了计算,并与Ansys软件解决方案进行了比较。结果表明,使用芳纶纤维可以减小接头的挠度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance Evaluation of RCC Beam Column Joint with Aramid Fibre
Abstract-In reinforced concrete structure beam, the beam column joints are more crucial zones which are most susceptible to failure during earthquake excitation. It is very important to design the joint to dissipate the large amount of energy to the neighbouring elements without loss of strength and ductility. Several retrofitting methods are employed to strengthen the beam column joint. The effective method one among is Fibre Reinforced Polymer (FRP) composites. In this paper, the deflection of beam column joint wrapped with aramid fibre has been calculated and it is compared with Ansys software solution. From the results, the deflection of the joint is decreased when aramid fibre is used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Moment Resisting Steel Connections for the Improvement of Light Gauge Cold Formed Steel Structures Mechanical Properties of Fiber Reinforced Concrete by using Sisal Fiber with M-Sand as Fine Aggregate Performance Evaluation of High-Performance Concrete with Steel Fiber Study on Physical and Mechanical Properties of Porous Concrete using Recycled Concrete Aggregate Investigation on Strength Properties of Concrete using Marble Powder for Ecofriendly Environment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1