{"title":"制造一种支架,用于准确和可重复地测量种植体周围口袋深度","authors":"H. Aggarwal, S. Singh, Kopal Goel, Rani Ranabhatt","doi":"10.4103/JDI.JDI_10_18","DOIUrl":null,"url":null,"abstract":"Pocket probing around dental implants is an important diagnostic procedure for the assessment of peri-implant status and evaluation of periodontal therapy. Conventionally, probing is done arbitrarily in the center of four aspects (mesial, distal, facial, and lingual/palatal) of implant without removal of the prosthesis. The prosthesis design leads to a steep convergence angle of probe insertion or possible penetration of peri-implant tissues which leads to incorrect measurement. The present technique describes a vacuum formed polyvinyl chloride stent that allows peri-implant pocket depth measurements to be performed repeatedly and reproducibly at pre- and post-rehabilitative recall appointments.","PeriodicalId":212982,"journal":{"name":"Journal of Dental Implants","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fabricating a stent for accurate and reproducible measurement of peri-implant pocket depth\",\"authors\":\"H. Aggarwal, S. Singh, Kopal Goel, Rani Ranabhatt\",\"doi\":\"10.4103/JDI.JDI_10_18\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Pocket probing around dental implants is an important diagnostic procedure for the assessment of peri-implant status and evaluation of periodontal therapy. Conventionally, probing is done arbitrarily in the center of four aspects (mesial, distal, facial, and lingual/palatal) of implant without removal of the prosthesis. The prosthesis design leads to a steep convergence angle of probe insertion or possible penetration of peri-implant tissues which leads to incorrect measurement. The present technique describes a vacuum formed polyvinyl chloride stent that allows peri-implant pocket depth measurements to be performed repeatedly and reproducibly at pre- and post-rehabilitative recall appointments.\",\"PeriodicalId\":212982,\"journal\":{\"name\":\"Journal of Dental Implants\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dental Implants\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/JDI.JDI_10_18\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dental Implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/JDI.JDI_10_18","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fabricating a stent for accurate and reproducible measurement of peri-implant pocket depth
Pocket probing around dental implants is an important diagnostic procedure for the assessment of peri-implant status and evaluation of periodontal therapy. Conventionally, probing is done arbitrarily in the center of four aspects (mesial, distal, facial, and lingual/palatal) of implant without removal of the prosthesis. The prosthesis design leads to a steep convergence angle of probe insertion or possible penetration of peri-implant tissues which leads to incorrect measurement. The present technique describes a vacuum formed polyvinyl chloride stent that allows peri-implant pocket depth measurements to be performed repeatedly and reproducibly at pre- and post-rehabilitative recall appointments.