智能电网反馈线性化分布式控制方案的鲁棒性分析

Abdallah K. Farraj, Eman M. Hammad, D. Kundur
{"title":"智能电网反馈线性化分布式控制方案的鲁棒性分析","authors":"Abdallah K. Farraj, Eman M. Hammad, D. Kundur","doi":"10.1109/PESGM.2015.7285954","DOIUrl":null,"url":null,"abstract":"Feedback linearization distributed control schemes have recently been proposed to stabilize power systems after the occurrence of a physical fault. This paper investigates the performance of feedback linearization distributed controllers in the presence of non-ideal practical measurement, communication and storage constraints. This work investigates the impact of sampling frequency, quantization depth, communication latency, signal-to-noise ratio, and limits on external power on the performance of the controllers. Results of this work detail the performance and effectiveness of the feedback linearization controllers in the New England 39-bus power system under these different practical limitations.","PeriodicalId":423639,"journal":{"name":"2015 IEEE Power & Energy Society General Meeting","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Robustness analysis of feedback linearization distributed control schemes in smart grid systems\",\"authors\":\"Abdallah K. Farraj, Eman M. Hammad, D. Kundur\",\"doi\":\"10.1109/PESGM.2015.7285954\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Feedback linearization distributed control schemes have recently been proposed to stabilize power systems after the occurrence of a physical fault. This paper investigates the performance of feedback linearization distributed controllers in the presence of non-ideal practical measurement, communication and storage constraints. This work investigates the impact of sampling frequency, quantization depth, communication latency, signal-to-noise ratio, and limits on external power on the performance of the controllers. Results of this work detail the performance and effectiveness of the feedback linearization controllers in the New England 39-bus power system under these different practical limitations.\",\"PeriodicalId\":423639,\"journal\":{\"name\":\"2015 IEEE Power & Energy Society General Meeting\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Power & Energy Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PESGM.2015.7285954\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2015.7285954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

反馈线性化分布式控制方案最近被提出用于电力系统发生物理故障后的稳定。研究了反馈线性化分布式控制器在非理想实际测量、通信和存储约束条件下的性能。这项工作研究了采样频率、量化深度、通信延迟、信噪比和外部电源限制对控制器性能的影响。这项工作的结果详细说明了反馈线性化控制器在这些不同的实际限制下在新英格兰39母线电力系统中的性能和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Robustness analysis of feedback linearization distributed control schemes in smart grid systems
Feedback linearization distributed control schemes have recently been proposed to stabilize power systems after the occurrence of a physical fault. This paper investigates the performance of feedback linearization distributed controllers in the presence of non-ideal practical measurement, communication and storage constraints. This work investigates the impact of sampling frequency, quantization depth, communication latency, signal-to-noise ratio, and limits on external power on the performance of the controllers. Results of this work detail the performance and effectiveness of the feedback linearization controllers in the New England 39-bus power system under these different practical limitations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Information theoretic index for regime shifts in power systems Optimal voltage regulation for unbalanced distribution networks considering distributed energy resources Evaluation of NERC's BRD frequency control standard in hydroelectric generation Distributed multi-agent scheme to improve dynamic voltage stability of distribution networks A multiagent system for residential DC microgrids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1