用于钎焊铜电接头的非晶金属箔

E. E. Zook
{"title":"用于钎焊铜电接头的非晶金属箔","authors":"E. E. Zook","doi":"10.1109/EIC.1985.7458613","DOIUrl":null,"url":null,"abstract":"Brazing of copper electrical conductors is of importance in power transformers, and uses a great amount of brazing material. The areas brazed are usually inside the coil, and consist of taps, leads, and splices. Since the brazing is done inside the coil care must be taken in the making of the joint to prevent insulation damage and annealing of the joint area due to the brazing temperatures. A new brazing foil with a lower melting temperature than the currently used AWS BCuP-5 [1] braze is on the market. This foil has an amorphous structure with a copper base, 7% phosphorous, and no silver. Due to its lower melting temperature there is less heat input in the base material during brazing, therefore, there is less likelihood of insulation damage, less annealing of the joint area, lower oxide buildup, and less time to effect a joint.","PeriodicalId":188957,"journal":{"name":"1985 EIC 17th Electrical/Electronics Insulation Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Amorphous metal foil for brazing copper electrical joints\",\"authors\":\"E. E. Zook\",\"doi\":\"10.1109/EIC.1985.7458613\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Brazing of copper electrical conductors is of importance in power transformers, and uses a great amount of brazing material. The areas brazed are usually inside the coil, and consist of taps, leads, and splices. Since the brazing is done inside the coil care must be taken in the making of the joint to prevent insulation damage and annealing of the joint area due to the brazing temperatures. A new brazing foil with a lower melting temperature than the currently used AWS BCuP-5 [1] braze is on the market. This foil has an amorphous structure with a copper base, 7% phosphorous, and no silver. Due to its lower melting temperature there is less heat input in the base material during brazing, therefore, there is less likelihood of insulation damage, less annealing of the joint area, lower oxide buildup, and less time to effect a joint.\",\"PeriodicalId\":188957,\"journal\":{\"name\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.1985.7458613\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1985 EIC 17th Electrical/Electronics Insulation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.1985.7458613","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

铜导体的钎焊在电力变压器中占有重要地位,需要使用大量的钎焊材料。钎焊的区域通常在线圈内部,由丝锥、引线和接头组成。由于钎焊是在线圈内部进行的,因此在制作接头时必须小心,以防止由于钎焊温度导致接头区域的绝缘损坏和退火。一种新的钎焊箔,其熔化温度比目前使用的AWS BCuP-5[1]钎焊更低。这种箔具有无定形结构,以铜为基材,含磷7%,不含银。由于其较低的熔化温度,在钎焊过程中,基底材料的热量输入较少,因此,绝缘损坏的可能性较小,接合区域的退火较少,氧化物积聚较少,并且影响接合的时间较少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Amorphous metal foil for brazing copper electrical joints
Brazing of copper electrical conductors is of importance in power transformers, and uses a great amount of brazing material. The areas brazed are usually inside the coil, and consist of taps, leads, and splices. Since the brazing is done inside the coil care must be taken in the making of the joint to prevent insulation damage and annealing of the joint area due to the brazing temperatures. A new brazing foil with a lower melting temperature than the currently used AWS BCuP-5 [1] braze is on the market. This foil has an amorphous structure with a copper base, 7% phosphorous, and no silver. Due to its lower melting temperature there is less heat input in the base material during brazing, therefore, there is less likelihood of insulation damage, less annealing of the joint area, lower oxide buildup, and less time to effect a joint.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A synthetic method for modelling transformer windings in the study of system switching transients Effect of environmental contamination on the formation of flashover on polymer insulating materials Evaluation of electrical insulation exposed to amorphous metal transformer core annealing temperature Plasma polymerization: A new process for electronics A new highly flexible flame retardant silicone rubber coated fiberglass sleeving
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1