中压电缆线路现场测量耗散系数值的解释方法

C. Freitag, I. Mladenovic, C. Weindl
{"title":"中压电缆线路现场测量耗散系数值的解释方法","authors":"C. Freitag, I. Mladenovic, C. Weindl","doi":"10.1109/ICSD.2013.6619784","DOIUrl":null,"url":null,"abstract":"In modern power utilities attention is especially directed to the condition determination of the network's electrical equipment, with the purpose of supporting the condition oriented asset management and maintenance strategies. In medium voltage (MV) networks, cables require the biggest investment capital. In order to point out the most suitable diagnostic parameters and their limits, a long lasting accelerated and artificial ageing experiment on MV paper insulated lead covered (PILC) cables was performed. The in this way determined dependencies of the diagnostic parameters on voltage, temperature and condition of the cables, as well as characteristic values and regarded failure probability play an immense role in the determination of cables' condition in field measurements. Still, the diagnostic criterion (e.g. in case of dissipation losses comparison of: absolute value, hysteresis, dependency on testing voltage) could significantly influence the final diagnostic statement. In addition, the recorded values have to be evaluated regarding the composition of the cable line. This problematic will be shown in the article and discussed on several exemplar field measurements.","PeriodicalId":437475,"journal":{"name":"2013 IEEE International Conference on Solid Dielectrics (ICSD)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An interpretation approach for in field measured dissipation factor values of MV cable lines\",\"authors\":\"C. Freitag, I. Mladenovic, C. Weindl\",\"doi\":\"10.1109/ICSD.2013.6619784\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In modern power utilities attention is especially directed to the condition determination of the network's electrical equipment, with the purpose of supporting the condition oriented asset management and maintenance strategies. In medium voltage (MV) networks, cables require the biggest investment capital. In order to point out the most suitable diagnostic parameters and their limits, a long lasting accelerated and artificial ageing experiment on MV paper insulated lead covered (PILC) cables was performed. The in this way determined dependencies of the diagnostic parameters on voltage, temperature and condition of the cables, as well as characteristic values and regarded failure probability play an immense role in the determination of cables' condition in field measurements. Still, the diagnostic criterion (e.g. in case of dissipation losses comparison of: absolute value, hysteresis, dependency on testing voltage) could significantly influence the final diagnostic statement. In addition, the recorded values have to be evaluated regarding the composition of the cable line. This problematic will be shown in the article and discussed on several exemplar field measurements.\",\"PeriodicalId\":437475,\"journal\":{\"name\":\"2013 IEEE International Conference on Solid Dielectrics (ICSD)\",\"volume\":\"26 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference on Solid Dielectrics (ICSD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.2013.6619784\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Solid Dielectrics (ICSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.2013.6619784","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在现代电力事业中,电网电气设备的状态确定尤其受到人们的关注,其目的是为了支持面向状态的资产管理和维护策略。在中压(MV)网络中,电缆需要最大的投资资金。为了找出最合适的诊断参数及其限值,对中压纸绝缘铅包电缆进行了长时间加速人工老化实验。通过这种方法确定的诊断参数对电缆电压、温度、状态的依赖关系,以及特征值和假定的失效概率,在现场测量中对电缆状态的确定起着巨大的作用。尽管如此,诊断标准(如耗散损耗比较:绝对值、迟滞、对测试电压的依赖性)对最终诊断结论有很大影响。此外,必须根据电缆线路的组成对记录值进行评估。这个问题将在文章中显示,并在几个范例现场测量中进行讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An interpretation approach for in field measured dissipation factor values of MV cable lines
In modern power utilities attention is especially directed to the condition determination of the network's electrical equipment, with the purpose of supporting the condition oriented asset management and maintenance strategies. In medium voltage (MV) networks, cables require the biggest investment capital. In order to point out the most suitable diagnostic parameters and their limits, a long lasting accelerated and artificial ageing experiment on MV paper insulated lead covered (PILC) cables was performed. The in this way determined dependencies of the diagnostic parameters on voltage, temperature and condition of the cables, as well as characteristic values and regarded failure probability play an immense role in the determination of cables' condition in field measurements. Still, the diagnostic criterion (e.g. in case of dissipation losses comparison of: absolute value, hysteresis, dependency on testing voltage) could significantly influence the final diagnostic statement. In addition, the recorded values have to be evaluated regarding the composition of the cable line. This problematic will be shown in the article and discussed on several exemplar field measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Contribution to the study of the amorphous phase of polyethylene terephtalate (PET) by the differential scanning calorimerty (DSC) experiments Influence of the thickness and the nature of HVAC insulator model on the flashover voltage and the leakage current Damage processes of polyimide film caused by surface discharge A modified method of suppressing narrow-band interference using FFT power spectrum Depths of chemical impurity states in Polyethylene; The big picture from first principles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1