{"title":"电压电流互感器在谐波测量中的计量性能","authors":"A. Cataliotti, V. Cosentino, G. Crotti, D. Giordano, M. Modarres, D. D. Cara, G. Tinè, D. Gallo, C. Landi, M. Luiso","doi":"10.1109/I2MTC.2018.8409694","DOIUrl":null,"url":null,"abstract":"In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by using test waveforms composed of a fundamental and one harmonic component. The harmonic ratio and phase errors are evaluated; the distortion effects on the errors on the fundamental component measurement are also investigated. The obtained results show how the metrological performances in harmonics measurement are influenced by both amplitude and phase shift of the harmonics.","PeriodicalId":393766,"journal":{"name":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"4320 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Metrological performances of voltage and current instrument transformers in harmonics measurements\",\"authors\":\"A. Cataliotti, V. Cosentino, G. Crotti, D. Giordano, M. Modarres, D. D. Cara, G. Tinè, D. Gallo, C. Landi, M. Luiso\",\"doi\":\"10.1109/I2MTC.2018.8409694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by using test waveforms composed of a fundamental and one harmonic component. The harmonic ratio and phase errors are evaluated; the distortion effects on the errors on the fundamental component measurement are also investigated. The obtained results show how the metrological performances in harmonics measurement are influenced by both amplitude and phase shift of the harmonics.\",\"PeriodicalId\":393766,\"journal\":{\"name\":\"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"4320 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2018.8409694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2018.8409694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

在新的电力系统场景中,非线性负载和可再生能源的增加使得谐波测量成为一项必不可少的任务。谐波测量的精度首先取决于所使用的电压和电流传感仪器变压器。由于互感器在非正弦条件下的性能并不总是很好地定义,本文对电流和电压互感器(ct和vt)在谐波存在下的计量性能进行了实验研究。定义了适当的测试程序,并为ct和vt校准开发了测量装置。用一个基波分量和一个谐波分量组成的测试波形进行分析。计算了谐波比和相位误差;研究了畸变对基分量测量误差的影响。结果表明,谐波的幅值和相移对谐波测量的计量性能有重要影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Metrological performances of voltage and current instrument transformers in harmonics measurements
In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by using test waveforms composed of a fundamental and one harmonic component. The harmonic ratio and phase errors are evaluated; the distortion effects on the errors on the fundamental component measurement are also investigated. The obtained results show how the metrological performances in harmonics measurement are influenced by both amplitude and phase shift of the harmonics.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Measurement of the void fraction of gas-liquid two-phase CO2 flow using laser attenuation techniques Improved interpolated dynamic DFT synchrophasor estimator considering second harmonic interferences Development of a new EMAT for multi-helical SH guided waves based on magnetostrictive effect A low cost master and slave distributed intelligent meter for non-intrusive load classification and anomaly warning Investigations into the behaviours of Coriolis flowmeters under air-water two-phase flow conditions on an optimized experimental platform
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1