加快综合保护体系中的保护方案

H. Zhang, Jinghan He, T. Yip, Z. Bo
{"title":"加快综合保护体系中的保护方案","authors":"H. Zhang, Jinghan He, T. Yip, Z. Bo","doi":"10.1109/ISGTEurope.2011.6162719","DOIUrl":null,"url":null,"abstract":"Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.","PeriodicalId":419250,"journal":{"name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","volume":"05 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accelerate protection scheme in integrated protection system\",\"authors\":\"H. Zhang, Jinghan He, T. Yip, Z. Bo\",\"doi\":\"10.1109/ISGTEurope.2011.6162719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.\",\"PeriodicalId\":419250,\"journal\":{\"name\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"volume\":\"05 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2011.6162719\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2011.6162719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

变压器是电力系统中最重要的元件之一,电流差动保护一直是变压器机组的主要保护技术。然而,由于CT饱和和变压器励磁涌流等问题,这种保护技术的灵敏度或可靠性较低。基于数字化变电站系统的研究发现,故障产生的电量不仅可以被继电器用来实现线路保护,还可以用于开发变压器保护技术。当发生故障时,保护系统可加快跳闸时间。仿真试验结果表明,该方法原理简单,可靠性好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accelerate protection scheme in integrated protection system
Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Power quality assessment of the Bogotá distribution network focused on voltage sag analysis Increasing security of supply by the use of a Local Power Controller during large system disturbances Realising the potential of smart grids in LV networks. Part 2: Microgeneration Multi-scale dynamic modeling to maximize demand side management Optimal fault location in distribution systems using distributed disturbance recordings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1