{"title":"加快综合保护体系中的保护方案","authors":"H. Zhang, Jinghan He, T. Yip, Z. Bo","doi":"10.1109/ISGTEurope.2011.6162719","DOIUrl":null,"url":null,"abstract":"Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.","PeriodicalId":419250,"journal":{"name":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","volume":"05 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accelerate protection scheme in integrated protection system\",\"authors\":\"H. Zhang, Jinghan He, T. Yip, Z. Bo\",\"doi\":\"10.1109/ISGTEurope.2011.6162719\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.\",\"PeriodicalId\":419250,\"journal\":{\"name\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"volume\":\"05 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2011.6162719\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2011.6162719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Accelerate protection scheme in integrated protection system
Transformer is one of the most important elements in power system, and current differential protection has been the main protection technique for transformer unit. This protection technique, however, suffers a low sensitivity or reliability due to the problems such as CT saturation and transformer magnetizing inrush. Based on digital substation system, studies have found that the fault generated electric quantities can not only be used by the relay to achieve the line protection but also used for developing transformer protection techniques. The protection system can accelerate trip time if fault happen. The results from simulation test show that the new method is with simple principle and good reliability.