Van-Hai Bui, A. Hussain, Thai-Thanh Nguyen, Hak-Man Kim
{"title":"并网模式下基于自动配置的微电网运行实时优化","authors":"Van-Hai Bui, A. Hussain, Thai-Thanh Nguyen, Hak-Man Kim","doi":"10.1109/ICSET.2016.7811771","DOIUrl":null,"url":null,"abstract":"The faults in a microgrid (MG) pose many challenges for operation of the system. They may lead to an increase in the operation cost. In this paper, in order to solve the problem, a novel algorithm based on the auto-configuration of MGs is proposed for minimizing the operation cost in grid-connected mode. A centralized energy management system (EMS) is also developed in accordance with the proposed algorithm, which is responsible for communication in the system and performs optimization. The EMS updates the system information and reschedules its resources upon occurrence of the faults or recovery from the faults for assuring economical operation of the MG system.","PeriodicalId":164446,"journal":{"name":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","volume":"139 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Real-time optimization for microgrid operation based on auto-configuration in grid-connected mode\",\"authors\":\"Van-Hai Bui, A. Hussain, Thai-Thanh Nguyen, Hak-Man Kim\",\"doi\":\"10.1109/ICSET.2016.7811771\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The faults in a microgrid (MG) pose many challenges for operation of the system. They may lead to an increase in the operation cost. In this paper, in order to solve the problem, a novel algorithm based on the auto-configuration of MGs is proposed for minimizing the operation cost in grid-connected mode. A centralized energy management system (EMS) is also developed in accordance with the proposed algorithm, which is responsible for communication in the system and performs optimization. The EMS updates the system information and reschedules its resources upon occurrence of the faults or recovery from the faults for assuring economical operation of the MG system.\",\"PeriodicalId\":164446,\"journal\":{\"name\":\"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)\",\"volume\":\"139 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSET.2016.7811771\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2016.7811771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Real-time optimization for microgrid operation based on auto-configuration in grid-connected mode
The faults in a microgrid (MG) pose many challenges for operation of the system. They may lead to an increase in the operation cost. In this paper, in order to solve the problem, a novel algorithm based on the auto-configuration of MGs is proposed for minimizing the operation cost in grid-connected mode. A centralized energy management system (EMS) is also developed in accordance with the proposed algorithm, which is responsible for communication in the system and performs optimization. The EMS updates the system information and reschedules its resources upon occurrence of the faults or recovery from the faults for assuring economical operation of the MG system.