{"title":"协同感应输电系统的效率比较","authors":"Quoc-Trinh Vo, Quang-Thang Duong, M. Okada","doi":"10.1109/ATC50776.2020.9255434","DOIUrl":null,"url":null,"abstract":"This paper presents the comparison of RF-RF efficiency and load voltage stability between cooperative inductive power transfer (IPT) system using common-coil relay and the one using separated-coil relay. Equivalent circuit technique is used to verify the load voltage stability and evaluate the RF-RF efficiency of the both systems. Electromagnetic simulation results highlighted that the cooperative IPT system using the common-coil relay outperforms the one using separated-coil relay in term of RF-RF efficiency while keeping the load voltages stable against the load variations. Furthermore, the advantage of cooperative IPT system using the common-coil relay over the one using separated-coil relay is still hold even though there is a misalignment of up to 20 percent of the half size of the coils.","PeriodicalId":218972,"journal":{"name":"2020 International Conference on Advanced Technologies for Communications (ATC)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Efficiency Comparison of Cooperative Inductive Power Transfer Systems\",\"authors\":\"Quoc-Trinh Vo, Quang-Thang Duong, M. Okada\",\"doi\":\"10.1109/ATC50776.2020.9255434\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the comparison of RF-RF efficiency and load voltage stability between cooperative inductive power transfer (IPT) system using common-coil relay and the one using separated-coil relay. Equivalent circuit technique is used to verify the load voltage stability and evaluate the RF-RF efficiency of the both systems. Electromagnetic simulation results highlighted that the cooperative IPT system using the common-coil relay outperforms the one using separated-coil relay in term of RF-RF efficiency while keeping the load voltages stable against the load variations. Furthermore, the advantage of cooperative IPT system using the common-coil relay over the one using separated-coil relay is still hold even though there is a misalignment of up to 20 percent of the half size of the coils.\",\"PeriodicalId\":218972,\"journal\":{\"name\":\"2020 International Conference on Advanced Technologies for Communications (ATC)\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 International Conference on Advanced Technologies for Communications (ATC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ATC50776.2020.9255434\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Conference on Advanced Technologies for Communications (ATC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ATC50776.2020.9255434","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文比较了采用共圈继电器和分离圈继电器的感应功率传输系统的RF-RF效率和负载电压稳定性。利用等效电路技术验证了负载电压的稳定性,并对两种系统的RF-RF效率进行了评估。电磁仿真结果表明,采用共圈继电器的协同IPT系统在RF-RF效率方面优于采用分离圈继电器的协同IPT系统,同时在负载变化时保持负载电压稳定。此外,使用共线圈继电器的合作IPT系统优于使用分离线圈继电器的IPT系统,即使存在高达线圈一半尺寸的20%的错位,也仍然保持优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Efficiency Comparison of Cooperative Inductive Power Transfer Systems
This paper presents the comparison of RF-RF efficiency and load voltage stability between cooperative inductive power transfer (IPT) system using common-coil relay and the one using separated-coil relay. Equivalent circuit technique is used to verify the load voltage stability and evaluate the RF-RF efficiency of the both systems. Electromagnetic simulation results highlighted that the cooperative IPT system using the common-coil relay outperforms the one using separated-coil relay in term of RF-RF efficiency while keeping the load voltages stable against the load variations. Furthermore, the advantage of cooperative IPT system using the common-coil relay over the one using separated-coil relay is still hold even though there is a misalignment of up to 20 percent of the half size of the coils.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Comparison of Three-node Two-way PLC Channel Models Vision based steering angle estimation for autonomous vehicles [Copyright notice] Orchestration of Wired and Wireless Systems for Future Mobile Transport Network Design, Fabrication Transmitter Modulator at S band for MicroSatellite with the direct RF input
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1