{"title":"带LLCL滤波器的单相电网逆变器谐振抑制方案","authors":"P. Alemi, Cheol-Ju Bae, Dong-Choon Lee","doi":"10.1109/PEAC.2014.7037907","DOIUrl":null,"url":null,"abstract":"This paper proposes a novel resonance suppression scheme for a single-phase grid inverter with the LLCL filters. In the structure of the LLCL filters, a small inductor is connected in series with the capacitor in the conventional LCL filters to make zero impedance at the switching frequency, by which the grid-side inductor filter can be reduced remarkably. However, since the resonance phenomenon is a critical issue in this case, a new control method using the proportional and resonant (PR) controllers is proposed to damp out the resonance. The simulation results have verified the effectiveness of the proposed control algorithm for a single-phase grid inverter.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Resonance suppression scheme in single-phase grid inverters with LLCL filters\",\"authors\":\"P. Alemi, Cheol-Ju Bae, Dong-Choon Lee\",\"doi\":\"10.1109/PEAC.2014.7037907\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a novel resonance suppression scheme for a single-phase grid inverter with the LLCL filters. In the structure of the LLCL filters, a small inductor is connected in series with the capacitor in the conventional LCL filters to make zero impedance at the switching frequency, by which the grid-side inductor filter can be reduced remarkably. However, since the resonance phenomenon is a critical issue in this case, a new control method using the proportional and resonant (PR) controllers is proposed to damp out the resonance. The simulation results have verified the effectiveness of the proposed control algorithm for a single-phase grid inverter.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7037907\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Resonance suppression scheme in single-phase grid inverters with LLCL filters
This paper proposes a novel resonance suppression scheme for a single-phase grid inverter with the LLCL filters. In the structure of the LLCL filters, a small inductor is connected in series with the capacitor in the conventional LCL filters to make zero impedance at the switching frequency, by which the grid-side inductor filter can be reduced remarkably. However, since the resonance phenomenon is a critical issue in this case, a new control method using the proportional and resonant (PR) controllers is proposed to damp out the resonance. The simulation results have verified the effectiveness of the proposed control algorithm for a single-phase grid inverter.