Ahmed F. Ebrahim, T. Youssef, S. Ahmed, S. Elmasry, O. Mohammed
{"title":"光伏并网逆变器故障检测与补偿","authors":"Ahmed F. Ebrahim, T. Youssef, S. Ahmed, S. Elmasry, O. Mohammed","doi":"10.1109/NAPS.2014.6965470","DOIUrl":null,"url":null,"abstract":"The main purpose of this paper is to propose a fault detection and fault tolerant control mechanism to maintain the continuous operation of the grid tied inverter, which is commonly used to interface renewable energy and distributed generation to the grid. The fault tolerance is provided using modified topology of the DC-AC power converter with redundant standby branch. The proposed system insures the continuous operation without isolating the energy source from the grid during faults on inverter switch. The fault may be open circuit fault or short circuit fault.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Fault detection and compensation for a PV system grid tie inverter\",\"authors\":\"Ahmed F. Ebrahim, T. Youssef, S. Ahmed, S. Elmasry, O. Mohammed\",\"doi\":\"10.1109/NAPS.2014.6965470\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main purpose of this paper is to propose a fault detection and fault tolerant control mechanism to maintain the continuous operation of the grid tied inverter, which is commonly used to interface renewable energy and distributed generation to the grid. The fault tolerance is provided using modified topology of the DC-AC power converter with redundant standby branch. The proposed system insures the continuous operation without isolating the energy source from the grid during faults on inverter switch. The fault may be open circuit fault or short circuit fault.\",\"PeriodicalId\":421766,\"journal\":{\"name\":\"2014 North American Power Symposium (NAPS)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2014.6965470\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault detection and compensation for a PV system grid tie inverter
The main purpose of this paper is to propose a fault detection and fault tolerant control mechanism to maintain the continuous operation of the grid tied inverter, which is commonly used to interface renewable energy and distributed generation to the grid. The fault tolerance is provided using modified topology of the DC-AC power converter with redundant standby branch. The proposed system insures the continuous operation without isolating the energy source from the grid during faults on inverter switch. The fault may be open circuit fault or short circuit fault.