光伏/热混合系统中热虹吸填充比的选择

Pedro Leineker Ochoski Machado, Victor Vaurek Dimbarre, R. Szmoski, Paulo Henrique DIAS DOS SANTOS, Thiago Antonini Alves
{"title":"光伏/热混合系统中热虹吸填充比的选择","authors":"Pedro Leineker Ochoski Machado, Victor Vaurek Dimbarre, R. Szmoski, Paulo Henrique DIAS DOS SANTOS, Thiago Antonini Alves","doi":"10.26678/abcm.creem2023.cre2023-0133","DOIUrl":null,"url":null,"abstract":". One alternative for clean energy production are photovoltaic panels, but these have low efficiency, especially when they are performing above their optimum operating temperature. Thus, the use of thermosyphons and heat pipes in PV panels is being increasingly studied, both for panel cooling and to compose a hybrid photovoltaic/thermal (PV/T) system. In this study, an experimental investigation was conducted on the thermal performance of thermosyphons with different filling ratios (30, 40, 50, and 60%) for application in a hybrid PV/thermal system. The investigation consisted in simulating the operation of the devices based on the heating of the evaporator by the Joule effect resulting from the dissipation of electrical energy on a resistive tape (10, 20, 30, 40, and 50W), and the cooling of the condenser by the water flow on its surface (18°C and 1L/min). The thermal analysis of the devices was based on the temperature distribution of the device regions over time, as well as their thermal resistance as a function of the applied thermal load. The results showed that the behavior of the thermosyphons with 30 and 60% filling ratios differed from the behavior of the other two devices, indicating that these filling ratios did not provide the correct operation of these devices. As for the thermal resistance analysis, it was verified that, in general, the 50% filling ratio resulted in lower thermal resistance values for the applied thermal loads, thus concluding that the device with the best thermal performance among those tested was the thermosyphon with a 50% filling ratio.","PeriodicalId":309145,"journal":{"name":"XXIX Congresso Nacional de Estudantes de Engenharia Mecânica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SELEÇÃO DA RAZÃO DE PREENCHIMENTO PARA TERMOSSIFÕES APLICADOS EM UM SISTEMA HÍBRIDO FOTOVOLTAICO/TÉRMICO\",\"authors\":\"Pedro Leineker Ochoski Machado, Victor Vaurek Dimbarre, R. Szmoski, Paulo Henrique DIAS DOS SANTOS, Thiago Antonini Alves\",\"doi\":\"10.26678/abcm.creem2023.cre2023-0133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\". One alternative for clean energy production are photovoltaic panels, but these have low efficiency, especially when they are performing above their optimum operating temperature. Thus, the use of thermosyphons and heat pipes in PV panels is being increasingly studied, both for panel cooling and to compose a hybrid photovoltaic/thermal (PV/T) system. In this study, an experimental investigation was conducted on the thermal performance of thermosyphons with different filling ratios (30, 40, 50, and 60%) for application in a hybrid PV/thermal system. The investigation consisted in simulating the operation of the devices based on the heating of the evaporator by the Joule effect resulting from the dissipation of electrical energy on a resistive tape (10, 20, 30, 40, and 50W), and the cooling of the condenser by the water flow on its surface (18°C and 1L/min). The thermal analysis of the devices was based on the temperature distribution of the device regions over time, as well as their thermal resistance as a function of the applied thermal load. The results showed that the behavior of the thermosyphons with 30 and 60% filling ratios differed from the behavior of the other two devices, indicating that these filling ratios did not provide the correct operation of these devices. As for the thermal resistance analysis, it was verified that, in general, the 50% filling ratio resulted in lower thermal resistance values for the applied thermal loads, thus concluding that the device with the best thermal performance among those tested was the thermosyphon with a 50% filling ratio.\",\"PeriodicalId\":309145,\"journal\":{\"name\":\"XXIX Congresso Nacional de Estudantes de Engenharia Mecânica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"XXIX Congresso Nacional de Estudantes de Engenharia Mecânica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26678/abcm.creem2023.cre2023-0133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"XXIX Congresso Nacional de Estudantes de Engenharia Mecânica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26678/abcm.creem2023.cre2023-0133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

. 清洁能源生产的另一种选择是光伏板,但它们的效率很低,特别是当它们的工作温度高于最佳工作温度时。因此,热虹吸管和热管在光伏板中的应用正得到越来越多的研究,既用于面板冷却,也用于组成光伏/热(PV/T)混合系统。本研究对不同填充率(30%、40%、50%和60%)的热虹吸管在光伏/热混合系统中的热性能进行了实验研究。研究包括通过电阻带上的电能耗散(10、20、30、40和50W)产生的焦耳效应加热蒸发器,以及通过其表面的水流(18°C和1L/min)冷却冷凝器,模拟装置的运行。器件的热分析是基于器件区域随时间的温度分布,以及它们的热阻作为所施加热负荷的函数。结果表明,30%和60%填充率的热虹吸管的行为与其他两种装置的行为不同,说明这些填充率并不能提供这些装置的正确操作。热阻分析方面,验证了一般情况下,填充率为50%时,所施加热负荷的热阻值较低,因此,在所有测试器件中,热性能最好的器件是填充率为50%的热虹吸管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SELEÇÃO DA RAZÃO DE PREENCHIMENTO PARA TERMOSSIFÕES APLICADOS EM UM SISTEMA HÍBRIDO FOTOVOLTAICO/TÉRMICO
. One alternative for clean energy production are photovoltaic panels, but these have low efficiency, especially when they are performing above their optimum operating temperature. Thus, the use of thermosyphons and heat pipes in PV panels is being increasingly studied, both for panel cooling and to compose a hybrid photovoltaic/thermal (PV/T) system. In this study, an experimental investigation was conducted on the thermal performance of thermosyphons with different filling ratios (30, 40, 50, and 60%) for application in a hybrid PV/thermal system. The investigation consisted in simulating the operation of the devices based on the heating of the evaporator by the Joule effect resulting from the dissipation of electrical energy on a resistive tape (10, 20, 30, 40, and 50W), and the cooling of the condenser by the water flow on its surface (18°C and 1L/min). The thermal analysis of the devices was based on the temperature distribution of the device regions over time, as well as their thermal resistance as a function of the applied thermal load. The results showed that the behavior of the thermosyphons with 30 and 60% filling ratios differed from the behavior of the other two devices, indicating that these filling ratios did not provide the correct operation of these devices. As for the thermal resistance analysis, it was verified that, in general, the 50% filling ratio resulted in lower thermal resistance values for the applied thermal loads, thus concluding that the device with the best thermal performance among those tested was the thermosyphon with a 50% filling ratio.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
STUDY OF THE AIR FLOW MEASUREMENT PARAMETER FOR INTERNAL COMBUSTION ENGINE TEST BENCHES Projeto de um experimento de Dessalinização de Água via Destilação por Membranas com vão de ar (AGMD) AVALIAÇÃO DA QUALIDADE DE PAINÉIS DE COMPENSADOS PLASTIFICADOS DE PARICÁ ANÁLISE DO DESGASTE ABRASIVO ENTRE AÇO INOX AISI 420 E AÇO CARBONO SAE 1045 APLICADO EM EQUIPAMENTOS DO RAMO DA CONSTRUÇÃO CIVIL Estudo experimental do desempenho térmico de um termossifão de aço inoxidável com resfriamento por convecção forçada
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1