{"title":"螺旋通量压缩发生器用电爆开关","authors":"D. Belt, J. Mankowski, A. Neuber, J. Dickens, M. Kristiansen","doi":"10.1109/MEGAGUSS.2006.4530702","DOIUrl":null,"url":null,"abstract":"Helical flux compression generators coupled with an inductive energy storage system have shown promising results as a driving source for High Power Microwave (HPM) loads. The output performance of the inductive energy storage system is contingent upon the opening switch scheme, usually an electro-explosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. By applying this fuse characterization model to an HFCG powered system, a non-optimized fuse has produced 60 kV into an HPM equivalent load with an HFCG output of 15 kA into a 3 muH inductor. Utilization of a non-explosive HFCG test-bed has produced 36 kV into an HPM equivalent load with an output of 15 kA into a 1.3 muH inductor. The use of a non-explosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. Prior analysis of fuse parameters has been accomplished with various materials including Silver (Au), Copper (Cu), and Aluminum (Al), but particular interest resides in the use of Gold (Ag) fuse material. We will discuss the a-priori calculated baseline fuse design and compare the experimental results of the gold wire material with the silver wire material baseline design. With the results presented, an accurate Pspice model applicable to our 45 kA HFCG systems will be available and allow the development of accurate modeling for higher current systems.","PeriodicalId":338246,"journal":{"name":"2006 IEEE International Conference on Megagauss Magnetic Field Generation and Related Topics","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Electro-Explosive Switches for Helical Flux Compression Generators\",\"authors\":\"D. Belt, J. Mankowski, A. Neuber, J. Dickens, M. Kristiansen\",\"doi\":\"10.1109/MEGAGUSS.2006.4530702\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Helical flux compression generators coupled with an inductive energy storage system have shown promising results as a driving source for High Power Microwave (HPM) loads. The output performance of the inductive energy storage system is contingent upon the opening switch scheme, usually an electro-explosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. By applying this fuse characterization model to an HFCG powered system, a non-optimized fuse has produced 60 kV into an HPM equivalent load with an HFCG output of 15 kA into a 3 muH inductor. Utilization of a non-explosive HFCG test-bed has produced 36 kV into an HPM equivalent load with an output of 15 kA into a 1.3 muH inductor. The use of a non-explosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. Prior analysis of fuse parameters has been accomplished with various materials including Silver (Au), Copper (Cu), and Aluminum (Al), but particular interest resides in the use of Gold (Ag) fuse material. We will discuss the a-priori calculated baseline fuse design and compare the experimental results of the gold wire material with the silver wire material baseline design. With the results presented, an accurate Pspice model applicable to our 45 kA HFCG systems will be available and allow the development of accurate modeling for higher current systems.\",\"PeriodicalId\":338246,\"journal\":{\"name\":\"2006 IEEE International Conference on Megagauss Magnetic Field Generation and Related Topics\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 IEEE International Conference on Megagauss Magnetic Field Generation and Related Topics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEGAGUSS.2006.4530702\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE International Conference on Megagauss Magnetic Field Generation and Related Topics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEGAGUSS.2006.4530702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

螺旋磁通压缩发生器与感应储能系统耦合作为高功率微波(HPM)负载的驱动源已显示出良好的效果。感应储能系统的输出性能取决于开路开关方案,通常是电爆保险丝。我们以前的工作涉及熔断器参数表征已经建立了潜在熔断器性能的基线。通过将该熔断器表征模型应用于HFCG供电系统,未经优化的熔断器已将60 kV产生为HPM等效负载,HFCG输出为15 kA,进入3 muH电感。利用非爆炸性HFCG试验台,在1.3 muH电感器中产生了输出为15ka的36kv HPM等效负载。使用非爆炸性HFCG试验台将允许验证保险丝参数模型的可扩展性,也允许测试外来保险丝材料。先前对熔断器参数的分析已经用各种材料完成,包括银(Au)、铜(Cu)和铝(Al),但特别感兴趣的是金(Ag)熔断器材料的使用。我们将讨论先验计算的基线熔断器设计,并将金丝材料与银丝材料基线设计的实验结果进行比较。根据所提出的结果,一个适用于我们的45 kA HFCG系统的精确Pspice模型将可用,并允许开发更高电流系统的精确建模。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electro-Explosive Switches for Helical Flux Compression Generators
Helical flux compression generators coupled with an inductive energy storage system have shown promising results as a driving source for High Power Microwave (HPM) loads. The output performance of the inductive energy storage system is contingent upon the opening switch scheme, usually an electro-explosive fuse. Our previous work involving fuse parameter characterization has established a baseline for potential fuse performance. By applying this fuse characterization model to an HFCG powered system, a non-optimized fuse has produced 60 kV into an HPM equivalent load with an HFCG output of 15 kA into a 3 muH inductor. Utilization of a non-explosive HFCG test-bed has produced 36 kV into an HPM equivalent load with an output of 15 kA into a 1.3 muH inductor. The use of a non-explosive HFCG test bed will allow the verification of scalability of the fuse parameter model and also allow testing of exotic fuse materials. Prior analysis of fuse parameters has been accomplished with various materials including Silver (Au), Copper (Cu), and Aluminum (Al), but particular interest resides in the use of Gold (Ag) fuse material. We will discuss the a-priori calculated baseline fuse design and compare the experimental results of the gold wire material with the silver wire material baseline design. With the results presented, an accurate Pspice model applicable to our 45 kA HFCG systems will be available and allow the development of accurate modeling for higher current systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Fabrication Method for a Mid-Sized, High-Energy-Density, Flux Compression Generator A Bench Top Railgun with Distributed Energy Sources and Diagonostics Computer Model of a Quasi-Force-Free Magnet with a 100-T Field Three-Dimensional Calculations of Electrical Parameters in Flux Compression Systems Quasi-Trapezoidal Shape Current Pulse Former Experimental Series ≪≪R-Damage≫≫
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1