Irwan Pernandi Sagala, D. Munir, A.Y.M. Rambe, T. Ashar
{"title":"棉兰市加油站工作人员嗅觉功能差异研究","authors":"Irwan Pernandi Sagala, D. Munir, A.Y.M. Rambe, T. Ashar","doi":"10.32734/SUMEJ.V1I1.446","DOIUrl":null,"url":null,"abstract":"Introduction: Chronic exposure of volatile substances can cause the impaired olfactory function. Objectives: In order to identify the difference of olfactory function in the workers of the Gas Station in Medan city. Methods: Analytical research with cross- sectional approach. The research subjects were 80 persons consisting of 40 gas station operators and 40 non-operators who fulfilled the inclusion and exclusion criteria. The applied statistical analysis was Mann Whitney, Fisher's Exact, Chi Square, T independent, Spearman with 95% confidence level. Results: Proportion of the impaired olfactory function in the gas station operator group by 77.5% and non-operator group by 0%. Significant correlation was obtained between age, duration of work with the impaired olfactory function (p = 0,047, p = 0,001). The gas station operators will suffer the impaired olfactory function if they work for 3.89 years. Conclusions: There were differences of olfactory functions in the gas station workers by using Sniffin 'Sticks Test in Medan city.","PeriodicalId":184699,"journal":{"name":"Sumatera Medical Journal","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Difference of Olfactory Functions in The Workers of The Gas Station by Using Sniffin’ Stickstest in Medan City\",\"authors\":\"Irwan Pernandi Sagala, D. Munir, A.Y.M. Rambe, T. Ashar\",\"doi\":\"10.32734/SUMEJ.V1I1.446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Chronic exposure of volatile substances can cause the impaired olfactory function. Objectives: In order to identify the difference of olfactory function in the workers of the Gas Station in Medan city. Methods: Analytical research with cross- sectional approach. The research subjects were 80 persons consisting of 40 gas station operators and 40 non-operators who fulfilled the inclusion and exclusion criteria. The applied statistical analysis was Mann Whitney, Fisher's Exact, Chi Square, T independent, Spearman with 95% confidence level. Results: Proportion of the impaired olfactory function in the gas station operator group by 77.5% and non-operator group by 0%. Significant correlation was obtained between age, duration of work with the impaired olfactory function (p = 0,047, p = 0,001). The gas station operators will suffer the impaired olfactory function if they work for 3.89 years. Conclusions: There were differences of olfactory functions in the gas station workers by using Sniffin 'Sticks Test in Medan city.\",\"PeriodicalId\":184699,\"journal\":{\"name\":\"Sumatera Medical Journal\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sumatera Medical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32734/SUMEJ.V1I1.446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sumatera Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32734/SUMEJ.V1I1.446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Difference of Olfactory Functions in The Workers of The Gas Station by Using Sniffin’ Stickstest in Medan City
Introduction: Chronic exposure of volatile substances can cause the impaired olfactory function. Objectives: In order to identify the difference of olfactory function in the workers of the Gas Station in Medan city. Methods: Analytical research with cross- sectional approach. The research subjects were 80 persons consisting of 40 gas station operators and 40 non-operators who fulfilled the inclusion and exclusion criteria. The applied statistical analysis was Mann Whitney, Fisher's Exact, Chi Square, T independent, Spearman with 95% confidence level. Results: Proportion of the impaired olfactory function in the gas station operator group by 77.5% and non-operator group by 0%. Significant correlation was obtained between age, duration of work with the impaired olfactory function (p = 0,047, p = 0,001). The gas station operators will suffer the impaired olfactory function if they work for 3.89 years. Conclusions: There were differences of olfactory functions in the gas station workers by using Sniffin 'Sticks Test in Medan city.