{"title":"并联运动MEMS XY纳米对位器的设计","authors":"Hongliang Shi, Yongsik Kim, Y. She","doi":"10.1109/ROBIO.2015.7419062","DOIUrl":null,"url":null,"abstract":"The purpose of this research is to design a novel parallel kinematic micro-electro-mechanical systems (MEMS) XY nanopositioner. It is challenging to design a MEMS XY positioner because of the limitations of fabrication, material property and actuation. The XY nanopositioner proposed in this manuscript is featured for decoupled motions, large stroke, compact size and large out-of-plane stiffness. This positioner includes three parts: thermal actuator, displacement amplifier and guide mechanism. The thermal actuator is applied to create a large electrothermal force for the in-plane motion. The lever based displacement amplifier is designed to increase the in-plane stroke. The symmetrical parallel guide mechanism is used to decouple the motions in the x and y directions while increasing the out-of-plane stiffness. Based on the Screw Theory, we derive an analytical model for the actuation and control of the stage. Furthermore, a Finite Element (FE) model is proposed to analyze the analytical model. By means of MEMS fabrication, the footprint of the XY nanopositioner is only 5 mm × 5 mm. However, the nanopositioner is capable of reaching a stroke of 83 μm × 83 μm. Compared with other designs, this parallel XY positioner has a large work space with a compact size.","PeriodicalId":325536,"journal":{"name":"2015 IEEE International Conference on Robotics and Biomimetics (ROBIO)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Design of a parallel kinematic MEMS XY nanopositioner\",\"authors\":\"Hongliang Shi, Yongsik Kim, Y. She\",\"doi\":\"10.1109/ROBIO.2015.7419062\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this research is to design a novel parallel kinematic micro-electro-mechanical systems (MEMS) XY nanopositioner. It is challenging to design a MEMS XY positioner because of the limitations of fabrication, material property and actuation. The XY nanopositioner proposed in this manuscript is featured for decoupled motions, large stroke, compact size and large out-of-plane stiffness. This positioner includes three parts: thermal actuator, displacement amplifier and guide mechanism. The thermal actuator is applied to create a large electrothermal force for the in-plane motion. The lever based displacement amplifier is designed to increase the in-plane stroke. The symmetrical parallel guide mechanism is used to decouple the motions in the x and y directions while increasing the out-of-plane stiffness. Based on the Screw Theory, we derive an analytical model for the actuation and control of the stage. Furthermore, a Finite Element (FE) model is proposed to analyze the analytical model. By means of MEMS fabrication, the footprint of the XY nanopositioner is only 5 mm × 5 mm. However, the nanopositioner is capable of reaching a stroke of 83 μm × 83 μm. Compared with other designs, this parallel XY positioner has a large work space with a compact size.\",\"PeriodicalId\":325536,\"journal\":{\"name\":\"2015 IEEE International Conference on Robotics and Biomimetics (ROBIO)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE International Conference on Robotics and Biomimetics (ROBIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROBIO.2015.7419062\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Conference on Robotics and Biomimetics (ROBIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBIO.2015.7419062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本研究的目的是设计一种新型的并联微机电系统(MEMS) XY纳米对位器。由于制造工艺、材料性能和驱动的限制,MEMS XY定位器的设计具有一定的挑战性。本文提出的XY纳米对位剂具有运动解耦、行程大、尺寸紧凑、面外刚度大等特点。该定位器由热致动器、位移放大器和导向机构三部分组成。应用热致动器为平面内运动产生较大的电热力。设计了基于杠杆的位移放大器,以增加平面行程。采用对称并联导轨机构对x、y方向运动进行解耦,同时增加了面外刚度。在螺旋理论的基础上,推导出了平台驱动与控制的解析模型。此外,还提出了一种有限元模型来对解析模型进行分析。通过MEMS制造,XY纳米对位器的占地面积仅为5mm × 5mm。然而,纳米对立剂能够达到83 μm × 83 μm的行程。与其他设计相比,该并联XY定位机具有体积小,工作空间大的特点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design of a parallel kinematic MEMS XY nanopositioner
The purpose of this research is to design a novel parallel kinematic micro-electro-mechanical systems (MEMS) XY nanopositioner. It is challenging to design a MEMS XY positioner because of the limitations of fabrication, material property and actuation. The XY nanopositioner proposed in this manuscript is featured for decoupled motions, large stroke, compact size and large out-of-plane stiffness. This positioner includes three parts: thermal actuator, displacement amplifier and guide mechanism. The thermal actuator is applied to create a large electrothermal force for the in-plane motion. The lever based displacement amplifier is designed to increase the in-plane stroke. The symmetrical parallel guide mechanism is used to decouple the motions in the x and y directions while increasing the out-of-plane stiffness. Based on the Screw Theory, we derive an analytical model for the actuation and control of the stage. Furthermore, a Finite Element (FE) model is proposed to analyze the analytical model. By means of MEMS fabrication, the footprint of the XY nanopositioner is only 5 mm × 5 mm. However, the nanopositioner is capable of reaching a stroke of 83 μm × 83 μm. Compared with other designs, this parallel XY positioner has a large work space with a compact size.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The current challenges and prospects of rain detection and removal from videos Minimization of the rate of change in torques during motion and force control under discontinuous constraints Target tracking for mobile robot based on Spatio-Temporal Context model Design of collision detection algorithms and force feedback for a virtual reality training intervention operation system A towing orbit transfer method of tethered space robots
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1