佛罗里达州农业和消费者服务部化学残留实验室使用的方法的验证。

G A Parker
{"title":"佛罗里达州农业和消费者服务部化学残留实验室使用的方法的验证。","authors":"G A Parker","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Very few methods for detecting residues of pesticides in food or agricultural samples have undergone rigorous colloborative study and possess official AOAC status. The Chemical Residue Laboratory has formalized a method validation scheme to use when incorporating or developing new, unofficial methods. These methods are validated by assessing certain performance parameters: scope, specificity, linear range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). For accuracy and precision assessment, 12 replicate fortifications must yield recoveries within the range of 70-120% with a coefficient of variation (CV) that compares favorably to the Horwitz CV. LOD and LOQ are equivalent to 3 and 10 times, respectively, the background signal contributed by a sample matrix blank. This criterion that we use for LOD/LOQ is not universal. In fact, because of differing definitions, we have encountered difficulties in enforcing a tolerance by using a registrant's method. This paper also presents an example of our method validation scheme, using a recent method development project for detecting sulfamethazine in raw milk. The sulfamethazine project also revealed unanticipated personnel problems, underscoring the importance of the human factor in quality assurance.</p>","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"74 5","pages":"868-71"},"PeriodicalIF":0.0000,"publicationDate":"1991-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of methods used in the Florida Department of Agricultural and Consumer Services' Chemical Residue Laboratory.\",\"authors\":\"G A Parker\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Very few methods for detecting residues of pesticides in food or agricultural samples have undergone rigorous colloborative study and possess official AOAC status. The Chemical Residue Laboratory has formalized a method validation scheme to use when incorporating or developing new, unofficial methods. These methods are validated by assessing certain performance parameters: scope, specificity, linear range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). For accuracy and precision assessment, 12 replicate fortifications must yield recoveries within the range of 70-120% with a coefficient of variation (CV) that compares favorably to the Horwitz CV. LOD and LOQ are equivalent to 3 and 10 times, respectively, the background signal contributed by a sample matrix blank. This criterion that we use for LOD/LOQ is not universal. In fact, because of differing definitions, we have encountered difficulties in enforcing a tolerance by using a registrant's method. This paper also presents an example of our method validation scheme, using a recent method development project for detecting sulfamethazine in raw milk. The sulfamethazine project also revealed unanticipated personnel problems, underscoring the importance of the human factor in quality assurance.</p>\",\"PeriodicalId\":14752,\"journal\":{\"name\":\"Journal - Association of Official Analytical Chemists\",\"volume\":\"74 5\",\"pages\":\"868-71\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal - Association of Official Analytical Chemists\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

很少有检测食品或农业样品中农药残留的方法经过严格的合作研究并获得官方的AOAC地位。化学残留实验室已正式制定了一套方法验证方案,以便在合并或开发新的非官方方法时使用。这些方法通过评估某些性能参数来验证:范围、特异性、线性范围、准确度、精密度、检出限(LOD)和定量限(LOQ)。对于准确度和精密度评估,12个重复强化的回收率必须在70-120%的范围内,变异系数(CV)优于霍维茨CV。LOD和LOQ分别相当于一个样本矩阵空白所贡献的背景信号的3倍和10倍。我们用于LOD/LOQ的这个标准并不是通用的。事实上,由于不同的定义,我们在使用注册者的方法来实施容忍度时遇到了困难。本文还介绍了我们的方法验证方案的一个例子,使用最近的方法开发项目检测原料奶中的磺胺乙胺。磺胺乙嘧啶项目还暴露了意想不到的人员问题,强调了人的因素在质量保证中的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation of methods used in the Florida Department of Agricultural and Consumer Services' Chemical Residue Laboratory.

Very few methods for detecting residues of pesticides in food or agricultural samples have undergone rigorous colloborative study and possess official AOAC status. The Chemical Residue Laboratory has formalized a method validation scheme to use when incorporating or developing new, unofficial methods. These methods are validated by assessing certain performance parameters: scope, specificity, linear range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). For accuracy and precision assessment, 12 replicate fortifications must yield recoveries within the range of 70-120% with a coefficient of variation (CV) that compares favorably to the Horwitz CV. LOD and LOQ are equivalent to 3 and 10 times, respectively, the background signal contributed by a sample matrix blank. This criterion that we use for LOD/LOQ is not universal. In fact, because of differing definitions, we have encountered difficulties in enforcing a tolerance by using a registrant's method. This paper also presents an example of our method validation scheme, using a recent method development project for detecting sulfamethazine in raw milk. The sulfamethazine project also revealed unanticipated personnel problems, underscoring the importance of the human factor in quality assurance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Liquid chromatographic determination of paralytic shellfish poisons in shellfish after prechromatographic oxidation. Liquid chromatographic determination of paraquat and diquat in crops using a silica column with aqueous ionic mobile phase. Enzymatic determination of free glutamic acid in dried soups and in minced sausages: NMKL collaborative study. Separation and determination of diesel contaminants in various fish products by capillary gas chromatography. Monitoring aldehyde production during frying by reversed-phase liquid chromatography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1