CT扫描辅助32片腹部切口对患者有效辐射剂量的估计

Nadiah Wanara, M. Hamdi, Salomo Sinuraya
{"title":"CT扫描辅助32片腹部切口对患者有效辐射剂量的估计","authors":"Nadiah Wanara, M. Hamdi, Salomo Sinuraya","doi":"10.31258/JKFI.17.2.80-86","DOIUrl":null,"url":null,"abstract":"Receipt of radiation doses in patients by CT scan media really contributed to the radio diagnostic field. So far, volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) are the dose parameters used as a prescription of the dose to the patients from the examination process on the CT scan. However, these parameters have the disadvantage that they only describe the dose output from the device without regard to patient size. Size Specific Dose Estimate (SSDE) is a dose correction based on patient size and an effective dose is the dose value that arises due to differences in biological sensitivity values. Calculation of SSDE values and total effective doses were carried out in this study from data of patients who had undergone an abdominal CT scan examination. Patient radiation dose data were obtained from documents collected from the Radiology Department at the Prima Pekanbaru hospital. The data was obtained from examination results of Toshiba Asterion Multi (CTB 400 tube) CT scan of the abdomen of 20 patients. The data analysis shows that the average value of SSDE for male and female patients are 19.64 mGy and 17.4 mGy and the average total effective dose for male and female patients are 12.63 mSv and 9.16 mSv. These data indicate that the level of radiation dose received by patients is below the threshold that has been evaluated based on BAPETEN provisions.","PeriodicalId":403286,"journal":{"name":"Komunikasi Fisika Indonesia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"ESTIMASI NILAI DOSIS RADIASI EFEKTIF PASIEN DARI CITRA MEDIS CT SCAN ASTEION MULTI 32 SLICE BAGIAN ABDOMEN\",\"authors\":\"Nadiah Wanara, M. Hamdi, Salomo Sinuraya\",\"doi\":\"10.31258/JKFI.17.2.80-86\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Receipt of radiation doses in patients by CT scan media really contributed to the radio diagnostic field. So far, volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) are the dose parameters used as a prescription of the dose to the patients from the examination process on the CT scan. However, these parameters have the disadvantage that they only describe the dose output from the device without regard to patient size. Size Specific Dose Estimate (SSDE) is a dose correction based on patient size and an effective dose is the dose value that arises due to differences in biological sensitivity values. Calculation of SSDE values and total effective doses were carried out in this study from data of patients who had undergone an abdominal CT scan examination. Patient radiation dose data were obtained from documents collected from the Radiology Department at the Prima Pekanbaru hospital. The data was obtained from examination results of Toshiba Asterion Multi (CTB 400 tube) CT scan of the abdomen of 20 patients. The data analysis shows that the average value of SSDE for male and female patients are 19.64 mGy and 17.4 mGy and the average total effective dose for male and female patients are 12.63 mSv and 9.16 mSv. These data indicate that the level of radiation dose received by patients is below the threshold that has been evaluated based on BAPETEN provisions.\",\"PeriodicalId\":403286,\"journal\":{\"name\":\"Komunikasi Fisika Indonesia\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Komunikasi Fisika Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31258/JKFI.17.2.80-86\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Komunikasi Fisika Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/JKFI.17.2.80-86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

通过CT扫描介质接收患者的辐射剂量确实对放射诊断领域做出了贡献。到目前为止,体积计算机断层扫描剂量指数(CTDIvol)和剂量长度乘积(DLP)是用来作为CT扫描检查过程中给患者剂量处方的剂量参数。然而,这些参数的缺点是它们只描述设备输出的剂量,而不考虑患者的大小。尺寸特定剂量估计(SSDE)是基于患者尺寸的剂量校正,有效剂量是由于生物敏感性值的差异而产生的剂量值。本研究根据接受腹部CT扫描检查的患者资料计算SSDE值和总有效剂量。患者辐射剂量数据来自普里玛北坎巴鲁医院放射科收集的文件。数据来源于20例患者腹部东芝Asterion Multi (CTB 400管)CT扫描检查结果。数据分析显示,男性和女性患者的SSDE平均值分别为19.64 mGy和17.4 mGy,男性和女性患者的平均总有效剂量分别为12.63 mSv和9.16 mSv。这些数据表明,患者接受的辐射剂量水平低于根据BAPETEN规定评估的阈值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ESTIMASI NILAI DOSIS RADIASI EFEKTIF PASIEN DARI CITRA MEDIS CT SCAN ASTEION MULTI 32 SLICE BAGIAN ABDOMEN
Receipt of radiation doses in patients by CT scan media really contributed to the radio diagnostic field. So far, volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) are the dose parameters used as a prescription of the dose to the patients from the examination process on the CT scan. However, these parameters have the disadvantage that they only describe the dose output from the device without regard to patient size. Size Specific Dose Estimate (SSDE) is a dose correction based on patient size and an effective dose is the dose value that arises due to differences in biological sensitivity values. Calculation of SSDE values and total effective doses were carried out in this study from data of patients who had undergone an abdominal CT scan examination. Patient radiation dose data were obtained from documents collected from the Radiology Department at the Prima Pekanbaru hospital. The data was obtained from examination results of Toshiba Asterion Multi (CTB 400 tube) CT scan of the abdomen of 20 patients. The data analysis shows that the average value of SSDE for male and female patients are 19.64 mGy and 17.4 mGy and the average total effective dose for male and female patients are 12.63 mSv and 9.16 mSv. These data indicate that the level of radiation dose received by patients is below the threshold that has been evaluated based on BAPETEN provisions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
AKTIVASI ZEOLIT ALAM SEBAGAI ADSORBEN PEWARNA ALAMI KULIT BUAH NAGA (PITAYA) ANALISIS HASIL KALIBRASI ALAT PHOTOTHERAPY MERK GEA MEDICAL TYPE XHZ-90 FABRIKASI ELEKTRODA KARBON DARI SABUT KELAPA MUDA DENGAN AKTIVASI FISIKA SEBAGAI APLIKASI SUPERKAPASITOR PENGARUH DOPING MANGAN TERHADAP KOMPOSISI DAN SIFAT KRISTALINITAS PARTIKEL OKSIDA BESI PASIR ALAM SUNGAI ROKAN DIPREPARASI DENGAN METODE BALL MILLING APLIKASI UJI COBA SKALA LABORATORIUM IMPLEMENTASI PROTOTYPE ALAT INOVASI TEKNOLOGI PASCA PANEN BERBASIS BIOMASSA UNTUK DETEKSI TEMPERATURE DENGAN SISTEM INTERNET OF THINGS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1