D. Choiński, W. Ilewicz, P. Krauze, Piotr Skupin, Zdzislaw Bielecki
{"title":"雾化过程中异丙醇浓度的在线分光光度测定","authors":"D. Choiński, W. Ilewicz, P. Krauze, Piotr Skupin, Zdzislaw Bielecki","doi":"10.1109/MMAR.2017.8046925","DOIUrl":null,"url":null,"abstract":"The paper presents preliminary results for online measurement method of isopropanol concentration in the ultrasonic nebulization process using BW-Tek compact UV/Vis spectrophotometer. The experimental setup with nebulization vessel was constructed with a probe for on-line measurements. The tests were performed using a standard mixture of isopropanol and water with the volume isopropanol concentration in the range 19% to 83%. The results of on-line spectrophotometric method were verified using stationary spectrophotometer and a gas chromatography method. Linear calibration for the obtained data was performed and measurement uncertainties for the tested method were evaluated as confidence intervals.","PeriodicalId":189753,"journal":{"name":"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On-line spectrophotometric measurements of isopropanol concentration in process of nebulization\",\"authors\":\"D. Choiński, W. Ilewicz, P. Krauze, Piotr Skupin, Zdzislaw Bielecki\",\"doi\":\"10.1109/MMAR.2017.8046925\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents preliminary results for online measurement method of isopropanol concentration in the ultrasonic nebulization process using BW-Tek compact UV/Vis spectrophotometer. The experimental setup with nebulization vessel was constructed with a probe for on-line measurements. The tests were performed using a standard mixture of isopropanol and water with the volume isopropanol concentration in the range 19% to 83%. The results of on-line spectrophotometric method were verified using stationary spectrophotometer and a gas chromatography method. Linear calibration for the obtained data was performed and measurement uncertainties for the tested method were evaluated as confidence intervals.\",\"PeriodicalId\":189753,\"journal\":{\"name\":\"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MMAR.2017.8046925\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 22nd International Conference on Methods and Models in Automation and Robotics (MMAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MMAR.2017.8046925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-line spectrophotometric measurements of isopropanol concentration in process of nebulization
The paper presents preliminary results for online measurement method of isopropanol concentration in the ultrasonic nebulization process using BW-Tek compact UV/Vis spectrophotometer. The experimental setup with nebulization vessel was constructed with a probe for on-line measurements. The tests were performed using a standard mixture of isopropanol and water with the volume isopropanol concentration in the range 19% to 83%. The results of on-line spectrophotometric method were verified using stationary spectrophotometer and a gas chromatography method. Linear calibration for the obtained data was performed and measurement uncertainties for the tested method were evaluated as confidence intervals.