配电系统抗电压跌落的鲁棒性:不同结构变化的分析评估

P. Caramia, P. Varilone, P. Verde, L. Vitale
{"title":"配电系统抗电压跌落的鲁棒性:不同结构变化的分析评估","authors":"P. Caramia, P. Varilone, P. Verde, L. Vitale","doi":"10.1109/ICHQP.2010.5625454","DOIUrl":null,"url":null,"abstract":"Electrical power system robustness is defined as the intrinsic capacity of an electrical power system to maintain assigned disturbance levels when external conditions change. In this paper the concept of robustness against is applied to the voltage dips, one of the most severe disturbances in power quality. Using graphical color schemes as immediate tools, improvements and/or degradations of the electrical power system robustness are assessed when the structure of distribution system is modified. In particular, both substitutions of components (from overhead to cable lines) and installation of new components (connection of DG units) are considered as possible structure modifications. The proposed tools are applied to different study cases.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"On the robustness of the distribution systems against voltage dips: The analytical assessment for different structure variations\",\"authors\":\"P. Caramia, P. Varilone, P. Verde, L. Vitale\",\"doi\":\"10.1109/ICHQP.2010.5625454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical power system robustness is defined as the intrinsic capacity of an electrical power system to maintain assigned disturbance levels when external conditions change. In this paper the concept of robustness against is applied to the voltage dips, one of the most severe disturbances in power quality. Using graphical color schemes as immediate tools, improvements and/or degradations of the electrical power system robustness are assessed when the structure of distribution system is modified. In particular, both substitutions of components (from overhead to cable lines) and installation of new components (connection of DG units) are considered as possible structure modifications. The proposed tools are applied to different study cases.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625454\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

电力系统鲁棒性是指当外部条件发生变化时,电力系统保持指定扰动水平的内在能力。本文将鲁棒性的概念应用于电压降这一电能质量中最严重的干扰之一。使用图形配色方案作为直接工具,评估配电系统结构修改时电力系统稳健性的改善和/或退化。特别是,替换组件(从架空到电缆线路)和安装新组件(DG机组的连接)都被认为是可能的结构修改。提出的工具应用于不同的研究案例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
On the robustness of the distribution systems against voltage dips: The analytical assessment for different structure variations
Electrical power system robustness is defined as the intrinsic capacity of an electrical power system to maintain assigned disturbance levels when external conditions change. In this paper the concept of robustness against is applied to the voltage dips, one of the most severe disturbances in power quality. Using graphical color schemes as immediate tools, improvements and/or degradations of the electrical power system robustness are assessed when the structure of distribution system is modified. In particular, both substitutions of components (from overhead to cable lines) and installation of new components (connection of DG units) are considered as possible structure modifications. The proposed tools are applied to different study cases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonic domain modeling of transformer nonlinear characteristic with piece-wise approximation Classification of Power Quality disturbances using the iterative Hilbert Huang Transform The problems of centralized decrease of harmonic voltages in the HV networks with distributed nonlinear loads Elimination of harmonics using multi-pulse rectifiers Power quality in public lighting systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1