{"title":"弯矩法分析钢筋混凝土结构的屏蔽性能","authors":"Zhang Senlin, Liu Qing, WU Guoqiang","doi":"10.1109/CEEM.2015.7368676","DOIUrl":null,"url":null,"abstract":"In this paper, the shielding performance of reinforced concrete construction is analyzed emplying the method of moment and equivalent principle. The surface of the reinforced concrete are modeled using rectangular surfaces patches. The surface of the reinforced concrete is assumed as metallized and modeled based on the equivalent principle. And the proposed technique has fewer unknown variables than MoM volume Integral equation solution, and is quicker in computation and more applicable to analyze the shielding performance of reinforced concrete building with complex structure. The comparison between the calculation results of this paper and FDTD, shows that the method is effective. And the shielding effectiveness of a real building in substation is analyzed at last.","PeriodicalId":442379,"journal":{"name":"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of shielding performance of reinforced concrete structures using the method of moment\",\"authors\":\"Zhang Senlin, Liu Qing, WU Guoqiang\",\"doi\":\"10.1109/CEEM.2015.7368676\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the shielding performance of reinforced concrete construction is analyzed emplying the method of moment and equivalent principle. The surface of the reinforced concrete are modeled using rectangular surfaces patches. The surface of the reinforced concrete is assumed as metallized and modeled based on the equivalent principle. And the proposed technique has fewer unknown variables than MoM volume Integral equation solution, and is quicker in computation and more applicable to analyze the shielding performance of reinforced concrete building with complex structure. The comparison between the calculation results of this paper and FDTD, shows that the method is effective. And the shielding effectiveness of a real building in substation is analyzed at last.\",\"PeriodicalId\":442379,\"journal\":{\"name\":\"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEEM.2015.7368676\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 7th Asia-Pacific Conference on Environmental Electromagnetics (CEEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEEM.2015.7368676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of shielding performance of reinforced concrete structures using the method of moment
In this paper, the shielding performance of reinforced concrete construction is analyzed emplying the method of moment and equivalent principle. The surface of the reinforced concrete are modeled using rectangular surfaces patches. The surface of the reinforced concrete is assumed as metallized and modeled based on the equivalent principle. And the proposed technique has fewer unknown variables than MoM volume Integral equation solution, and is quicker in computation and more applicable to analyze the shielding performance of reinforced concrete building with complex structure. The comparison between the calculation results of this paper and FDTD, shows that the method is effective. And the shielding effectiveness of a real building in substation is analyzed at last.