相移PWM与三次谐波注入过调制范围操作

D. Baimel, R. Rabinovici, S. Tapuchi
{"title":"相移PWM与三次谐波注入过调制范围操作","authors":"D. Baimel, R. Rabinovici, S. Tapuchi","doi":"10.1109/SPEEDAM.2014.6872050","DOIUrl":null,"url":null,"abstract":"The paper presents novel Phase Shifted PWM method for multi-level inverters operated in the over-modulation range. The proposed method is based on combination of Generic Phase Shifted PWM method with third harmonic injection method. The first significant advantage of the proposed method over the conventional Phase Disposition (PD) PWM is equal power flow between the H-bridges and almost equal distribution of the switching operations number between them. Furthermore, it provides improved linearity in the over-modulation range. The proposed method is analyzed by extensive simulation results. Several aspects as Total Harmonic Distortion Factor of the inverter output currents, and voltages, harmonic content, frequency spectrum distribution and switchings number are studied.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Phase shifted PWM with third harmonic injection for over-modulation range operation\",\"authors\":\"D. Baimel, R. Rabinovici, S. Tapuchi\",\"doi\":\"10.1109/SPEEDAM.2014.6872050\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper presents novel Phase Shifted PWM method for multi-level inverters operated in the over-modulation range. The proposed method is based on combination of Generic Phase Shifted PWM method with third harmonic injection method. The first significant advantage of the proposed method over the conventional Phase Disposition (PD) PWM is equal power flow between the H-bridges and almost equal distribution of the switching operations number between them. Furthermore, it provides improved linearity in the over-modulation range. The proposed method is analyzed by extensive simulation results. Several aspects as Total Harmonic Distortion Factor of the inverter output currents, and voltages, harmonic content, frequency spectrum distribution and switchings number are studied.\",\"PeriodicalId\":344918,\"journal\":{\"name\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"volume\":\"44 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEEDAM.2014.6872050\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6872050","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

提出了一种适用于过调制范围的多电平逆变器的移相PWM方法。该方法是将通用移相PWM方法与三次谐波注入方法相结合的方法。与传统的相位配置(PD) PWM相比,该方法的第一个显著优点是h桥之间的功率流相等,并且它们之间的开关操作次数分布几乎相等。此外,它在过调制范围内提供了更好的线性度。通过大量的仿真结果对该方法进行了分析。从逆变器输出电流和电压的总谐波失真系数、谐波含量、频谱分布和开关数等方面进行了研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Phase shifted PWM with third harmonic injection for over-modulation range operation
The paper presents novel Phase Shifted PWM method for multi-level inverters operated in the over-modulation range. The proposed method is based on combination of Generic Phase Shifted PWM method with third harmonic injection method. The first significant advantage of the proposed method over the conventional Phase Disposition (PD) PWM is equal power flow between the H-bridges and almost equal distribution of the switching operations number between them. Furthermore, it provides improved linearity in the over-modulation range. The proposed method is analyzed by extensive simulation results. Several aspects as Total Harmonic Distortion Factor of the inverter output currents, and voltages, harmonic content, frequency spectrum distribution and switchings number are studied.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A wireless controlled circuit for PV panel disconnection in case of fire Voltage stabilization in weak grids by high power charging stations Concepts for an integration of quick charging stations in weak power grids Some lab experiments on the control of an aircraft electrical landing gear Controller Hardware-In-the-Loop validation of a magnetic core saturation algorithm for fault ride-through evaluations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1