基于个性化分类器的智能手机光容积脉搏波信号运动和噪声伪影检测

F. Tabei, B. Askarian, J. Chong
{"title":"基于个性化分类器的智能手机光容积脉搏波信号运动和噪声伪影检测","authors":"F. Tabei, B. Askarian, J. Chong","doi":"10.1109/HI-POCT45284.2019.8962833","DOIUrl":null,"url":null,"abstract":"Health parameters such as heart rhythm, blood pressure, and the level of oxygen saturation in the blood could be measured with photoplethysmography (PPG) signal. The advent of smartphone camera sensors has enabled the extraction of PPG signals from smartphones. PPG signals are weak at motion and noise artifacts (MNA) which could generate unreliable heart rate measurement. Smartphone PPG signals are more prone to MNA since they are not designed for clinical applications. PPG signals are known as biometric signals since they have unique behaviors for each individual. However, in previous MNA detection studies this personalized characteristic has not been considered. In this paper, we propose a novel personalized MNA detection method by applying a probabilistic neural network as a classifier. The performance of our personalized method is evaluated with 25 volunteered subjects in terms of accuracy, specificity, and sensitivity and compared with the generalized method. The average accuracy of our personalized method is 97.96% while it is 92.94% in the generalized one. The average values of personalized specificity and sensitivity are 99.69% and 93.91% while the generalized classifier gives 95.38% and 87.4%.","PeriodicalId":269346,"journal":{"name":"2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Motion and Noise Artifact Detection in Smartphone Photoplethysmograph Signals Using Personalized Classifier\",\"authors\":\"F. Tabei, B. Askarian, J. Chong\",\"doi\":\"10.1109/HI-POCT45284.2019.8962833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Health parameters such as heart rhythm, blood pressure, and the level of oxygen saturation in the blood could be measured with photoplethysmography (PPG) signal. The advent of smartphone camera sensors has enabled the extraction of PPG signals from smartphones. PPG signals are weak at motion and noise artifacts (MNA) which could generate unreliable heart rate measurement. Smartphone PPG signals are more prone to MNA since they are not designed for clinical applications. PPG signals are known as biometric signals since they have unique behaviors for each individual. However, in previous MNA detection studies this personalized characteristic has not been considered. In this paper, we propose a novel personalized MNA detection method by applying a probabilistic neural network as a classifier. The performance of our personalized method is evaluated with 25 volunteered subjects in terms of accuracy, specificity, and sensitivity and compared with the generalized method. The average accuracy of our personalized method is 97.96% while it is 92.94% in the generalized one. The average values of personalized specificity and sensitivity are 99.69% and 93.91% while the generalized classifier gives 95.38% and 87.4%.\",\"PeriodicalId\":269346,\"journal\":{\"name\":\"2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HI-POCT45284.2019.8962833\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Healthcare Innovations and Point of Care Technologies, (HI-POCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HI-POCT45284.2019.8962833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

健康参数,如心律,血压,血氧饱和度水平可以测量光容积脉搏波(PPG)信号。智能手机相机传感器的出现使得从智能手机中提取PPG信号成为可能。在运动和噪声伪影(MNA)下,PPG信号很弱,可能会产生不可靠的心率测量。智能手机PPG信号更容易发生MNA,因为它们不是为临床应用而设计的。PPG信号被称为生物特征信号,因为它们对每个个体都有独特的行为。然而,在以前的MNA检测研究中,没有考虑到这种个性化特征。本文提出了一种基于概率神经网络的个性化MNA检测方法。我们的个性化方法在准确性、特异性和敏感性方面对25名志愿者进行了评估,并与广义方法进行了比较。个性化方法的平均准确率为97.96%,广义方法的平均准确率为92.94%。个性化特异性和敏感性的平均值分别为99.69%和93.91%,广义分类器的平均值分别为95.38%和87.4%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Motion and Noise Artifact Detection in Smartphone Photoplethysmograph Signals Using Personalized Classifier
Health parameters such as heart rhythm, blood pressure, and the level of oxygen saturation in the blood could be measured with photoplethysmography (PPG) signal. The advent of smartphone camera sensors has enabled the extraction of PPG signals from smartphones. PPG signals are weak at motion and noise artifacts (MNA) which could generate unreliable heart rate measurement. Smartphone PPG signals are more prone to MNA since they are not designed for clinical applications. PPG signals are known as biometric signals since they have unique behaviors for each individual. However, in previous MNA detection studies this personalized characteristic has not been considered. In this paper, we propose a novel personalized MNA detection method by applying a probabilistic neural network as a classifier. The performance of our personalized method is evaluated with 25 volunteered subjects in terms of accuracy, specificity, and sensitivity and compared with the generalized method. The average accuracy of our personalized method is 97.96% while it is 92.94% in the generalized one. The average values of personalized specificity and sensitivity are 99.69% and 93.91% while the generalized classifier gives 95.38% and 87.4%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Novel Nanoscale Electrode for Biosensing A Motion Free Image Based TRF Reader for Quantitative Immunoassay Gaze-based video games for assessment of attention outside of the lab Conjugated Barcoded Particles for Multiplexed Biomarker Quantification with a Microfluidic Biochip Daily Locomotor Movement Recognition with a Smart Insole and a Pre-defined Route Map: Towards Early Motor Dysfunction Detection*
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1