{"title":"一个简单的低成本筛选试验微量白蛋白尿","authors":"H. Peiris, A. Keerthi, U. Hewage, D. Fernando","doi":"10.4038/CJMS.V46I2.4850","DOIUrl":null,"url":null,"abstract":"Estimation of urinary albumin excretion in micro quantities requires expensive immunochemical methods which are not freely available in developing countries with limited resources. A study was performed to set up a simple cost-effective test to quantitatively assess the microalbuminuria. Urine specimens (173 samples) were collected and albumin concentration was estimated by precipitating with 25% sulphosalicylic acid (SSA) and use of a light dependent resistor (LDR) system. As the sensitivity of LDR system was interfered by the colour pigment of urine, all samples were run through a Sephadex G-25 micro column to separate the colour pigment. The present test detects albumin concentrations in the range 10-200 mg/L with a sensitivity and specificity values of 83 and 79% respectively. We conclude that the present LDR micro column gel filtration method can be used as a cost -effective screening test for microalbuminuria in developing countries.","PeriodicalId":253405,"journal":{"name":"Ceylon Journal of Medical Science","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A simple cost-effective screening test for microalbuminuria\",\"authors\":\"H. Peiris, A. Keerthi, U. Hewage, D. Fernando\",\"doi\":\"10.4038/CJMS.V46I2.4850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Estimation of urinary albumin excretion in micro quantities requires expensive immunochemical methods which are not freely available in developing countries with limited resources. A study was performed to set up a simple cost-effective test to quantitatively assess the microalbuminuria. Urine specimens (173 samples) were collected and albumin concentration was estimated by precipitating with 25% sulphosalicylic acid (SSA) and use of a light dependent resistor (LDR) system. As the sensitivity of LDR system was interfered by the colour pigment of urine, all samples were run through a Sephadex G-25 micro column to separate the colour pigment. The present test detects albumin concentrations in the range 10-200 mg/L with a sensitivity and specificity values of 83 and 79% respectively. We conclude that the present LDR micro column gel filtration method can be used as a cost -effective screening test for microalbuminuria in developing countries.\",\"PeriodicalId\":253405,\"journal\":{\"name\":\"Ceylon Journal of Medical Science\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ceylon Journal of Medical Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4038/CJMS.V46I2.4850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceylon Journal of Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4038/CJMS.V46I2.4850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A simple cost-effective screening test for microalbuminuria
Estimation of urinary albumin excretion in micro quantities requires expensive immunochemical methods which are not freely available in developing countries with limited resources. A study was performed to set up a simple cost-effective test to quantitatively assess the microalbuminuria. Urine specimens (173 samples) were collected and albumin concentration was estimated by precipitating with 25% sulphosalicylic acid (SSA) and use of a light dependent resistor (LDR) system. As the sensitivity of LDR system was interfered by the colour pigment of urine, all samples were run through a Sephadex G-25 micro column to separate the colour pigment. The present test detects albumin concentrations in the range 10-200 mg/L with a sensitivity and specificity values of 83 and 79% respectively. We conclude that the present LDR micro column gel filtration method can be used as a cost -effective screening test for microalbuminuria in developing countries.