百岁老人的血压和心率计时器。

Chronobiologia Pub Date : 1991-10-01
O Ikonomov, G Stoynev, G Cornélissen, A Stoynev, D Hillman, N Madjirova, R Kane, F Halberg
{"title":"百岁老人的血压和心率计时器。","authors":"O Ikonomov,&nbsp;G Stoynev,&nbsp;G Cornélissen,&nbsp;A Stoynev,&nbsp;D Hillman,&nbsp;N Madjirova,&nbsp;R Kane,&nbsp;F Halberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Rhythm characteristics of blood pressure (BP) and heart rate (Hr) of 11 healthy centenarians and 66 medical students are described. Each subject ambulatorily monitored measured BP and HR around the clock at 15-min intervals for 48 hours. Least-squares spectra were obtained by the fit of cosine curves (cosinor) and compared between the two populations. Confounding by geographic differences seems to be ruled out by comparisons with results from international data bases. A shift in prominence from the circadian domain to higher frequency harmonics was found for the BP but not for the HR of centenarians. In clinically mostly healthy centenarians, markers of primary aging may consist of a relatively low circadian BP and HR amplitude and a tendency toward internal and external desynchronization. Whether these chronobiologic changes with age are desirable, indifferent or undesirable can now be elucidated by outcome studies, in the light of the reference standards provided herein.</p>","PeriodicalId":75705,"journal":{"name":"Chronobiologia","volume":"18 4","pages":"167-79"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The blood pressure and heart rate chronome of centenarians.\",\"authors\":\"O Ikonomov,&nbsp;G Stoynev,&nbsp;G Cornélissen,&nbsp;A Stoynev,&nbsp;D Hillman,&nbsp;N Madjirova,&nbsp;R Kane,&nbsp;F Halberg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Rhythm characteristics of blood pressure (BP) and heart rate (Hr) of 11 healthy centenarians and 66 medical students are described. Each subject ambulatorily monitored measured BP and HR around the clock at 15-min intervals for 48 hours. Least-squares spectra were obtained by the fit of cosine curves (cosinor) and compared between the two populations. Confounding by geographic differences seems to be ruled out by comparisons with results from international data bases. A shift in prominence from the circadian domain to higher frequency harmonics was found for the BP but not for the HR of centenarians. In clinically mostly healthy centenarians, markers of primary aging may consist of a relatively low circadian BP and HR amplitude and a tendency toward internal and external desynchronization. Whether these chronobiologic changes with age are desirable, indifferent or undesirable can now be elucidated by outcome studies, in the light of the reference standards provided herein.</p>\",\"PeriodicalId\":75705,\"journal\":{\"name\":\"Chronobiologia\",\"volume\":\"18 4\",\"pages\":\"167-79\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chronobiologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chronobiologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了11名健康百岁老人和66名医学生的血压(BP)和心率(Hr)的节律特征。每名受试者在48小时内每隔15分钟动态监测测量的血压和心率。通过余弦曲线的拟合得到最小二乘光谱,并对两个种群进行了比较。通过与国际数据库的结果进行比较,似乎排除了地理差异造成的混淆。在百岁老人的血压中发现了从昼夜节律域到高频谐波的突出转变,但在HR中没有发现。在临床上大多数健康的百岁老人中,原发性衰老的标志可能包括相对较低的昼夜BP和HR振幅以及内部和外部不同步的趋势。这些随年龄变化的时间生物学变化是可取的、无关紧要的还是不可取的,现在可以根据本文提供的参考标准,通过结果研究来阐明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The blood pressure and heart rate chronome of centenarians.

Rhythm characteristics of blood pressure (BP) and heart rate (Hr) of 11 healthy centenarians and 66 medical students are described. Each subject ambulatorily monitored measured BP and HR around the clock at 15-min intervals for 48 hours. Least-squares spectra were obtained by the fit of cosine curves (cosinor) and compared between the two populations. Confounding by geographic differences seems to be ruled out by comparisons with results from international data bases. A shift in prominence from the circadian domain to higher frequency harmonics was found for the BP but not for the HR of centenarians. In clinically mostly healthy centenarians, markers of primary aging may consist of a relatively low circadian BP and HR amplitude and a tendency toward internal and external desynchronization. Whether these chronobiologic changes with age are desirable, indifferent or undesirable can now be elucidated by outcome studies, in the light of the reference standards provided herein.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Cardiovascular disease risk monitoring in the light of chronobioethics. Dora K. (Holly) Hayes. Agostino Carandente. Models for chronobiologic risk and prepathology detection. A tribute to Bill W. Kennedy. Cross-spectral coherence between geomagnetic disturbance and human cardiovascular variables at non-societal frequencies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1