{"title":"粘结桥的制备与金属调节作用的临床比较。故障统计分析]。","authors":"P Rammelsberg, W Gernet, P Pospiech, M Pahle","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A total of 107 bonded bridges could be re-evaluated after a mean period of 2.3 years and a maximum of 5 years. The preparation of mechanical retentive aids, such as grooves and bores resulted in a significant reduction of failure rates after one year. Electrolytical etching or silicoating of the CoCr restorations failed to have any effect on the failure rates of those bridges that were provided with adequate mechanical retention.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 10","pages":"653-6"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Clinical comparison of bonded bridges as a function of preparation and metal conditioning. Statistical analysis of failures].\",\"authors\":\"P Rammelsberg, W Gernet, P Pospiech, M Pahle\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A total of 107 bonded bridges could be re-evaluated after a mean period of 2.3 years and a maximum of 5 years. The preparation of mechanical retentive aids, such as grooves and bores resulted in a significant reduction of failure rates after one year. Electrolytical etching or silicoating of the CoCr restorations failed to have any effect on the failure rates of those bridges that were provided with adequate mechanical retention.</p>\",\"PeriodicalId\":11244,\"journal\":{\"name\":\"Deutsche zahnarztliche Zeitschrift\",\"volume\":\"46 10\",\"pages\":\"653-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Deutsche zahnarztliche Zeitschrift\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Clinical comparison of bonded bridges as a function of preparation and metal conditioning. Statistical analysis of failures].
A total of 107 bonded bridges could be re-evaluated after a mean period of 2.3 years and a maximum of 5 years. The preparation of mechanical retentive aids, such as grooves and bores resulted in a significant reduction of failure rates after one year. Electrolytical etching or silicoating of the CoCr restorations failed to have any effect on the failure rates of those bridges that were provided with adequate mechanical retention.