{"title":"MPPT SEPIC变流器和PV单相逆变器的模糊控制器","authors":"A. E. El Khateb, N. Rahim, J. Selvaraj","doi":"10.1109/ISIEA.2011.6108693","DOIUrl":null,"url":null,"abstract":"This paper introduces an implementation of Fuzzy Logic Controller (FLC) for the single-ended primary-inductor converter (SEPIC) that control the maximum power point tracking (MPPT) signal together with the cascaded single-phase inverter. The extracting of the maximum power through using the SEPIC fuzzy controller is considered the main improvement here. Fuzzy-controlling in duty cycle increases/decreases the voltage level for the SEPIC according to the maximum power. SEPIC MPPT ensures optimal utilization for the PV array. The controller further proves its accuracy in variable-load conditions. TMS320F28335 DSP has been used to implement the controlled pulse width modulation (PWM). The controlled system has been verified by simulation and implemented in a prototype. Then, experimental results have been compared with those for conventional single-phase inverter.","PeriodicalId":110449,"journal":{"name":"2011 IEEE Symposium on Industrial Electronics and Applications","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":"{\"title\":\"Fuzzy Logic Controller for MPPT SEPIC converter and PV single-phase inverter\",\"authors\":\"A. E. El Khateb, N. Rahim, J. Selvaraj\",\"doi\":\"10.1109/ISIEA.2011.6108693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces an implementation of Fuzzy Logic Controller (FLC) for the single-ended primary-inductor converter (SEPIC) that control the maximum power point tracking (MPPT) signal together with the cascaded single-phase inverter. The extracting of the maximum power through using the SEPIC fuzzy controller is considered the main improvement here. Fuzzy-controlling in duty cycle increases/decreases the voltage level for the SEPIC according to the maximum power. SEPIC MPPT ensures optimal utilization for the PV array. The controller further proves its accuracy in variable-load conditions. TMS320F28335 DSP has been used to implement the controlled pulse width modulation (PWM). The controlled system has been verified by simulation and implemented in a prototype. Then, experimental results have been compared with those for conventional single-phase inverter.\",\"PeriodicalId\":110449,\"journal\":{\"name\":\"2011 IEEE Symposium on Industrial Electronics and Applications\",\"volume\":\"48 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"26\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE Symposium on Industrial Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIEA.2011.6108693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Symposium on Industrial Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIEA.2011.6108693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fuzzy Logic Controller for MPPT SEPIC converter and PV single-phase inverter
This paper introduces an implementation of Fuzzy Logic Controller (FLC) for the single-ended primary-inductor converter (SEPIC) that control the maximum power point tracking (MPPT) signal together with the cascaded single-phase inverter. The extracting of the maximum power through using the SEPIC fuzzy controller is considered the main improvement here. Fuzzy-controlling in duty cycle increases/decreases the voltage level for the SEPIC according to the maximum power. SEPIC MPPT ensures optimal utilization for the PV array. The controller further proves its accuracy in variable-load conditions. TMS320F28335 DSP has been used to implement the controlled pulse width modulation (PWM). The controlled system has been verified by simulation and implemented in a prototype. Then, experimental results have been compared with those for conventional single-phase inverter.