利用虚拟同步发电机增强并网光伏电站的FRT和暂态稳定

M. Islam, M. Mannan, Md. Rifat Hazari
{"title":"利用虚拟同步发电机增强并网光伏电站的FRT和暂态稳定","authors":"M. Islam, M. Mannan, Md. Rifat Hazari","doi":"10.53799/ajse.v20i4.171","DOIUrl":null,"url":null,"abstract":"Due to the extensive integration of renewable energy sources (RESs), i.e., photovoltaic (PV) system, the future power system is developing into an inverter-based system from a dominated alternator-based power system. This massive penetration of inverter-based PV system reduced the system inertia and damping characteristics of the power grid, impacting the fault ride-through (FRT) capability and causes frequency instability. Modern grid codes require that PV systems should work in the same way as conventional power plants and assist the system during transient state. However, most of the conventional inverter control mechanisms failed to fulfill the requirements of grid codes, especially when the penetration ratio of the PV system is close to the conventional unit. Therefore, this paper proposes a virtual synchronous generator (VSG) control mechanism of PV system inverter to augment FRT competency and frequency stability. The proposed VSG control system mimics the behavior of conventional power plants. To observe and evaluate the proposed controller behavior, simulation analyses were executed in the PSCAD/EMTDC software for both proposed and conventional controllers. The simulation results clearly indicate that the proposed VSG control system has sufficient damping characteristics to ensure FRT capability and frequency stability.       ","PeriodicalId":224436,"journal":{"name":"AIUB Journal of Science and Engineering (AJSE)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"FRT and Transient Stability Augmentation of Grid-Connected PV Station Using Virtual Synchronous Generator\",\"authors\":\"M. Islam, M. Mannan, Md. Rifat Hazari\",\"doi\":\"10.53799/ajse.v20i4.171\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to the extensive integration of renewable energy sources (RESs), i.e., photovoltaic (PV) system, the future power system is developing into an inverter-based system from a dominated alternator-based power system. This massive penetration of inverter-based PV system reduced the system inertia and damping characteristics of the power grid, impacting the fault ride-through (FRT) capability and causes frequency instability. Modern grid codes require that PV systems should work in the same way as conventional power plants and assist the system during transient state. However, most of the conventional inverter control mechanisms failed to fulfill the requirements of grid codes, especially when the penetration ratio of the PV system is close to the conventional unit. Therefore, this paper proposes a virtual synchronous generator (VSG) control mechanism of PV system inverter to augment FRT competency and frequency stability. The proposed VSG control system mimics the behavior of conventional power plants. To observe and evaluate the proposed controller behavior, simulation analyses were executed in the PSCAD/EMTDC software for both proposed and conventional controllers. The simulation results clearly indicate that the proposed VSG control system has sufficient damping characteristics to ensure FRT capability and frequency stability.       \",\"PeriodicalId\":224436,\"journal\":{\"name\":\"AIUB Journal of Science and Engineering (AJSE)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AIUB Journal of Science and Engineering (AJSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53799/ajse.v20i4.171\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AIUB Journal of Science and Engineering (AJSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53799/ajse.v20i4.171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于可再生能源(RESs)即光伏(PV)系统的广泛集成,未来的电力系统正从以交流发电机为主的电力系统向以逆变器为主的电力系统发展。基于逆变器的光伏系统的大规模渗透降低了电网的系统惯性和阻尼特性,影响了故障穿越(FRT)能力并导致频率不稳定。现代电网规范要求光伏发电系统应以与传统电厂相同的方式工作,并在暂态状态下辅助系统。然而,传统的逆变器控制机制大多不能满足电网规范的要求,特别是当光伏系统的渗透比接近常规机组时。为此,本文提出了一种光伏系统逆变器的虚拟同步发电机(VSG)控制机制,以增强其FRT能力和频率稳定性。所提出的VSG控制系统模拟了传统电厂的运行行为。为了观察和评估所提出的控制器的行为,在PSCAD/EMTDC软件中对所提出的控制器和传统控制器进行了仿真分析。仿真结果清楚地表明,所提出的VSG控制系统具有足够的阻尼特性,以保证FRT能力和频率稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
FRT and Transient Stability Augmentation of Grid-Connected PV Station Using Virtual Synchronous Generator
Due to the extensive integration of renewable energy sources (RESs), i.e., photovoltaic (PV) system, the future power system is developing into an inverter-based system from a dominated alternator-based power system. This massive penetration of inverter-based PV system reduced the system inertia and damping characteristics of the power grid, impacting the fault ride-through (FRT) capability and causes frequency instability. Modern grid codes require that PV systems should work in the same way as conventional power plants and assist the system during transient state. However, most of the conventional inverter control mechanisms failed to fulfill the requirements of grid codes, especially when the penetration ratio of the PV system is close to the conventional unit. Therefore, this paper proposes a virtual synchronous generator (VSG) control mechanism of PV system inverter to augment FRT competency and frequency stability. The proposed VSG control system mimics the behavior of conventional power plants. To observe and evaluate the proposed controller behavior, simulation analyses were executed in the PSCAD/EMTDC software for both proposed and conventional controllers. The simulation results clearly indicate that the proposed VSG control system has sufficient damping characteristics to ensure FRT capability and frequency stability.       
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance Prediction of A Power Generation Gas Turbine Using An Optimized Artificial Neural Network Model Advancing Fuzzy Logic: A Hierarchical Fuzzy System Approach WVEHDD: Weighted Voting based Ensemble System for Heart Disease Detection Predictions of Malaysia Age-Specific Fertility Rates using the Lee-Carter and the Functional Data Approaches Performance Analysis of Automatic Generation Control for a Multi-Area Interconnected System Using Genetic Algorithm and Particle Swarm Optimization Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1