{"title":"一种预期故障隔离位移开关的识别方法","authors":"C. Long, Yufei Teng, Zhenchao Jiang, Jie Wu, Peng Zhang, Shi Jing","doi":"10.1109/ICSGCE.2018.8556750","DOIUrl":null,"url":null,"abstract":"After setting expected failure during power grid operation risk assessment, failure isolation contains two steps, one is to identify the switches that should be disconnected, which are called shift switches, the other is to disconnect the shift switches. This paper proposes a method of identifying shift switch of expected failure isolation, where substation topology and complex wiring are considered. First, from the viewpoint of failure isolating effect, failure elements are classified into independent elements and element groups. Second, element group and its composition are obtained according to its structural features. Then, the method of identifying shift switches of failure isolations for all kinds of failure elements is established. Finally, the proposed method is validated by applying it to classical failures of a practical power grid.","PeriodicalId":366392,"journal":{"name":"2018 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Method of Identifying Shift Switch of Expected Failure Isolation\",\"authors\":\"C. Long, Yufei Teng, Zhenchao Jiang, Jie Wu, Peng Zhang, Shi Jing\",\"doi\":\"10.1109/ICSGCE.2018.8556750\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"After setting expected failure during power grid operation risk assessment, failure isolation contains two steps, one is to identify the switches that should be disconnected, which are called shift switches, the other is to disconnect the shift switches. This paper proposes a method of identifying shift switch of expected failure isolation, where substation topology and complex wiring are considered. First, from the viewpoint of failure isolating effect, failure elements are classified into independent elements and element groups. Second, element group and its composition are obtained according to its structural features. Then, the method of identifying shift switches of failure isolations for all kinds of failure elements is established. Finally, the proposed method is validated by applying it to classical failures of a practical power grid.\",\"PeriodicalId\":366392,\"journal\":{\"name\":\"2018 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE)\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSGCE.2018.8556750\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSGCE.2018.8556750","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在电网运行风险评估中设定预期故障后,故障隔离包括两个步骤,一是确定应断开的开关,称为换挡开关,二是断开换挡开关。本文提出了一种考虑变电站拓扑结构和复杂布线的预期故障隔离位移开关识别方法。首先,从失效隔离效果的角度出发,将失效单元划分为独立单元和单元群。其次,根据其结构特征得到元素群及其组成;在此基础上,建立了各种失效元件的故障隔离位移开关识别方法。最后,将该方法应用于实际电网的典型故障,验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Method of Identifying Shift Switch of Expected Failure Isolation
After setting expected failure during power grid operation risk assessment, failure isolation contains two steps, one is to identify the switches that should be disconnected, which are called shift switches, the other is to disconnect the shift switches. This paper proposes a method of identifying shift switch of expected failure isolation, where substation topology and complex wiring are considered. First, from the viewpoint of failure isolating effect, failure elements are classified into independent elements and element groups. Second, element group and its composition are obtained according to its structural features. Then, the method of identifying shift switches of failure isolations for all kinds of failure elements is established. Finally, the proposed method is validated by applying it to classical failures of a practical power grid.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ICT Requirements and Challenges for Provision of Grid Services from Renewable Generation Plants A Low-Cost and Energy-Efficient Smart Dust Cleaning Technique for Solar Panel System Design and Implementation of a Maximum Power Point Tracking Algorithm for Wind Turbines Using PLC-SCADA On the Investigation and Experimental Analysis of Energy-Efficient Lighting for a University Building Investigation and Analyses of Energy-Efficient Technologies for HVAC and Lighting Systems via Energy Auditing Processes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1