有功能量流向快速变化下标准功率/能量度量的性能

J. Drapela, J. Morávek, Lukáš Radil, P. Mastný
{"title":"有功能量流向快速变化下标准功率/能量度量的性能","authors":"J. Drapela, J. Morávek, Lukáš Radil, P. Mastný","doi":"10.1109/ICHQP46026.2020.9177900","DOIUrl":null,"url":null,"abstract":"Rapid and frequent changes in energy flow direction, those may occur in active distribution systems due to presence of (un)intentional generation with simultaneous consumption, have significant effect on correctness and consequent interpretation of measured power and registered energy by power analyzers and revenue meters based on standard metric with long measuring window. The loss of information because of averaging effect in measuring window is explained and investigated using a numerical model of standard window based metric considering four invariant parameters. Moreover, identified characteristics are verified by means of performed experiments on a set of typical revenue meters. Finally, proposed solution is presented in the conclusion.","PeriodicalId":436720,"journal":{"name":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Performance of Standard Power/Energy Metric under Fast Changes in Active Energy Flow Direction\",\"authors\":\"J. Drapela, J. Morávek, Lukáš Radil, P. Mastný\",\"doi\":\"10.1109/ICHQP46026.2020.9177900\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Rapid and frequent changes in energy flow direction, those may occur in active distribution systems due to presence of (un)intentional generation with simultaneous consumption, have significant effect on correctness and consequent interpretation of measured power and registered energy by power analyzers and revenue meters based on standard metric with long measuring window. The loss of information because of averaging effect in measuring window is explained and investigated using a numerical model of standard window based metric considering four invariant parameters. Moreover, identified characteristics are verified by means of performed experiments on a set of typical revenue meters. Finally, proposed solution is presented in the conclusion.\",\"PeriodicalId\":436720,\"journal\":{\"name\":\"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP46026.2020.9177900\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP46026.2020.9177900","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在有功配电系统中,由于同时存在(非)有意发电而导致的能量流方向的快速和频繁变化,对基于长测量窗口的标准度量的功率分析仪和收益表对测量功率和登记能量的正确性和后续解释产生了重大影响。利用考虑四个不变参数的标准窗度量的数值模型,解释和研究了测量窗口平均效应造成的信息损失。此外,通过在一组典型的收入计上进行的实验,验证了所识别的特性。最后,在结论部分提出了解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance of Standard Power/Energy Metric under Fast Changes in Active Energy Flow Direction
Rapid and frequent changes in energy flow direction, those may occur in active distribution systems due to presence of (un)intentional generation with simultaneous consumption, have significant effect on correctness and consequent interpretation of measured power and registered energy by power analyzers and revenue meters based on standard metric with long measuring window. The loss of information because of averaging effect in measuring window is explained and investigated using a numerical model of standard window based metric considering four invariant parameters. Moreover, identified characteristics are verified by means of performed experiments on a set of typical revenue meters. Finally, proposed solution is presented in the conclusion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Important Considerations in Development of PV Inverter Models for High Frequency Emission (Supraharmonic) Studies Transient response of single-phase photovoltaic inverters to step changes in supply voltage distortion ICHQP 2020 Title Page Current Practice on Power Quality Legislation within European Transmission Systems – Results from Horizon 2020 Project MIGRATE Evaluation of Jacobian used in Simulation of Nonlinear Circuits in the Modified Harmonic Domain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1