高速电梯系统动态负载模拟器

Hyung-Min Ryu, Sung-Jun Kim, S. Sul, T. Kwon, Ki-Su Kim, Young-Seok Shim, Ki-Riong Seok
{"title":"高速电梯系统动态负载模拟器","authors":"Hyung-Min Ryu, Sung-Jun Kim, S. Sul, T. Kwon, Ki-Su Kim, Young-Seok Shim, Ki-Riong Seok","doi":"10.1109/PCC.2002.997638","DOIUrl":null,"url":null,"abstract":"This paper describes the load simulator for a high-speed elevator, which can emulate a 3-mass system as well as the equivalent 1-mass system. In order to implement the equivalent inertia of the entire elevator system, the conventional simulators have generally utilized mechanical inertia (flywheel) with large radius, which makes the entire system large and heavy. In addition, the mechanical inertia should be replaced each time in order to test another elevator system. In this paper, the dynamic load simulation methods using electrical inertia are presented so that the volume and weight of the simulator system are greatly reduced and the adjustment of inertia value can be achieved easily by software. Experimental results show the feasibility of this simulator system.","PeriodicalId":320424,"journal":{"name":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"Dynamic load simulator for high-speed elevator system\",\"authors\":\"Hyung-Min Ryu, Sung-Jun Kim, S. Sul, T. Kwon, Ki-Su Kim, Young-Seok Shim, Ki-Riong Seok\",\"doi\":\"10.1109/PCC.2002.997638\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the load simulator for a high-speed elevator, which can emulate a 3-mass system as well as the equivalent 1-mass system. In order to implement the equivalent inertia of the entire elevator system, the conventional simulators have generally utilized mechanical inertia (flywheel) with large radius, which makes the entire system large and heavy. In addition, the mechanical inertia should be replaced each time in order to test another elevator system. In this paper, the dynamic load simulation methods using electrical inertia are presented so that the volume and weight of the simulator system are greatly reduced and the adjustment of inertia value can be achieved easily by software. Experimental results show the feasibility of this simulator system.\",\"PeriodicalId\":320424,\"journal\":{\"name\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-08-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCC.2002.997638\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Power Conversion Conference-Osaka 2002 (Cat. No.02TH8579)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCC.2002.997638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

本文介绍了一种高速电梯负载模拟器,既可以模拟三质量系统,也可以模拟等效的一质量系统。为了实现整个电梯系统的等效惯量,传统的仿真器一般采用大半径的机械惯量(飞轮),使得整个系统又大又重。此外,每次应更换机械惯量,以便测试另一个电梯系统。本文提出了利用电惯量进行动态负载仿真的方法,从而大大减小了仿真系统的体积和重量,并且可以通过软件方便地实现惯量值的调整。实验结果表明了该仿真系统的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dynamic load simulator for high-speed elevator system
This paper describes the load simulator for a high-speed elevator, which can emulate a 3-mass system as well as the equivalent 1-mass system. In order to implement the equivalent inertia of the entire elevator system, the conventional simulators have generally utilized mechanical inertia (flywheel) with large radius, which makes the entire system large and heavy. In addition, the mechanical inertia should be replaced each time in order to test another elevator system. In this paper, the dynamic load simulation methods using electrical inertia are presented so that the volume and weight of the simulator system are greatly reduced and the adjustment of inertia value can be achieved easily by software. Experimental results show the feasibility of this simulator system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
High-power-factor single-phase switch clamped rectifier AC chopper using four switches Latest development of soft switching inverter power supply using active clamp scheme with a charge up function for magnetron drive Low cost highly efficient of complete PV system Extended Kalman filter tuning in sensorless PMSM drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1