脉冲氧浓度验证

Umi Salamah, Asna Nur Izziyah, A. Raharjo
{"title":"脉冲氧浓度验证","authors":"Umi Salamah, Asna Nur Izziyah, A. Raharjo","doi":"10.23960/JTAF.V8I2.2588","DOIUrl":null,"url":null,"abstract":"The level of oxygen saturation in the blood is important to know the health condition of the body. If the human body lacks or excess oxygen, it will cause illness and other bodily system work disorders. One of the tools to detect the oxygen saturation level is the Pulse oximeter. Previous research has successfully designed a Pulse oximeter based on Arduino. The pulse oximeter produces a photoplethysmograph (PPG) signal that corresponds to the standard PPG signals in 20 test samples. PPG signals can be processed to provide information on oxygen saturation (SpO2) levels in the blood. In this research, validation of the Pulse oximeter is compared with a commercial pulse oximeter, the digital oximeter JZK-301. The results obtained from this validation are the smallest deviation errors are 4.83% while the largest errata is 22.51%. The greatest accuracy of 95.17%, of respondents number 16 and the smallest accuracy is 77, 49%, that is the number of respondents 12. The average deviation of 20 data is 12.82% with the resulting accuracy is 87, 18%. This indicates that the self-designed pulse oximeter has good efficiency and can be developed further","PeriodicalId":314761,"journal":{"name":"Jurnal Teori dan Aplikasi Fisika","volume":"65 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Validasi Pulse oximeter dalam Penentuan Kadar Oksigen dalam Darah\",\"authors\":\"Umi Salamah, Asna Nur Izziyah, A. Raharjo\",\"doi\":\"10.23960/JTAF.V8I2.2588\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The level of oxygen saturation in the blood is important to know the health condition of the body. If the human body lacks or excess oxygen, it will cause illness and other bodily system work disorders. One of the tools to detect the oxygen saturation level is the Pulse oximeter. Previous research has successfully designed a Pulse oximeter based on Arduino. The pulse oximeter produces a photoplethysmograph (PPG) signal that corresponds to the standard PPG signals in 20 test samples. PPG signals can be processed to provide information on oxygen saturation (SpO2) levels in the blood. In this research, validation of the Pulse oximeter is compared with a commercial pulse oximeter, the digital oximeter JZK-301. The results obtained from this validation are the smallest deviation errors are 4.83% while the largest errata is 22.51%. The greatest accuracy of 95.17%, of respondents number 16 and the smallest accuracy is 77, 49%, that is the number of respondents 12. The average deviation of 20 data is 12.82% with the resulting accuracy is 87, 18%. This indicates that the self-designed pulse oximeter has good efficiency and can be developed further\",\"PeriodicalId\":314761,\"journal\":{\"name\":\"Jurnal Teori dan Aplikasi Fisika\",\"volume\":\"65 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Teori dan Aplikasi Fisika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23960/JTAF.V8I2.2588\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teori dan Aplikasi Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23960/JTAF.V8I2.2588","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

血液中的氧饱和度对了解身体的健康状况很重要。如果人体缺氧或过量,就会引起疾病和其他身体系统工作障碍。检测血氧饱和度水平的工具之一是脉搏血氧计。之前的研究已经成功地设计了一个基于Arduino的脉搏血氧仪。脉搏血氧仪产生的光容积脉搏波(PPG)信号与20个测试样本中的标准PPG信号相对应。PPG信号可以被处理以提供血液中氧饱和度(SpO2)水平的信息。在本研究中,将脉搏血氧仪的验证与商用脉搏血氧仪JZK-301进行了比较。验证结果表明,最小偏差误差为4.83%,最大偏差误差为22.51%。最大准确率为95.17%,即应答者16人,最小准确率为77.49%,即应答者12人。20个数据的平均偏差为12.82%,准确度为87.18%。这表明自行设计的脉搏血氧仪具有良好的效率,可以进一步发展
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validasi Pulse oximeter dalam Penentuan Kadar Oksigen dalam Darah
The level of oxygen saturation in the blood is important to know the health condition of the body. If the human body lacks or excess oxygen, it will cause illness and other bodily system work disorders. One of the tools to detect the oxygen saturation level is the Pulse oximeter. Previous research has successfully designed a Pulse oximeter based on Arduino. The pulse oximeter produces a photoplethysmograph (PPG) signal that corresponds to the standard PPG signals in 20 test samples. PPG signals can be processed to provide information on oxygen saturation (SpO2) levels in the blood. In this research, validation of the Pulse oximeter is compared with a commercial pulse oximeter, the digital oximeter JZK-301. The results obtained from this validation are the smallest deviation errors are 4.83% while the largest errata is 22.51%. The greatest accuracy of 95.17%, of respondents number 16 and the smallest accuracy is 77, 49%, that is the number of respondents 12. The average deviation of 20 data is 12.82% with the resulting accuracy is 87, 18%. This indicates that the self-designed pulse oximeter has good efficiency and can be developed further
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rancang Bangun Alat Ukur Tingkat Manis Buah Jeruk Menggunakan Sensor Kapasitor Semi Silinder Berbasis Arduino Analisis Pengaruh Ukuran Lantai Muatan Timbangan Terhadap Nilai Error Pada Pengujian Eksentrisitas Timbangan Elektronik Sesuai OIML R76 Dynamic Viscosity Measurement Method Based on the Stokes Drag of Prolate Ellipsoidal Mass Analisis Kuantum pada Rangkaian LC dengan Pendekatan Fungsi Gelombang Radial Persamaan Schrȍdinger Potensial Osilator Harmonik Electric Field Controlled Anisotropic Rashba Splitting in Janus Chromium Dichalcogenide Monolayers : A Computational Study based on Density Functional Theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1