{"title":"使用单个麦克风的全被动回声消除器","authors":"T. Tazawa, T. Hatashima, N. Ohnishi, N. Sugei","doi":"10.1109/IMTC.1994.351841","DOIUrl":null,"url":null,"abstract":"There are many studies on removal or suppression of reverberation. Among them, the approach, in which the impulse-response in a room is measured beforehand, has obtained very satisfactory results. An impulse-response is, however, not invariant, and changes with time depending on the room temperature and humidity, and the relative location between a sound source and a set of microphones. It is troublesome to measure an impulse response exactly each time. So, we have tried to cancel echoes using only one acoustic signal with echoes, obtained through a single microphone. In order to cancel echoes, we have to determine both delay times and amplitude ratios between direct sound and each of reflected sounds. Delay times are obtained as peaks of cepstrum of acoustic signal. Each amplitude ratio is iteratively searched so that resultant recovered sound may have the shortest duration. In the case that there are a few reflected signals, the result of experiment with reverberated signal synthesized using CD sound shows good recovery of an original sound.<<ETX>>","PeriodicalId":231484,"journal":{"name":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A fully passive echo-canceler using a single microphone\",\"authors\":\"T. Tazawa, T. Hatashima, N. Ohnishi, N. Sugei\",\"doi\":\"10.1109/IMTC.1994.351841\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"There are many studies on removal or suppression of reverberation. Among them, the approach, in which the impulse-response in a room is measured beforehand, has obtained very satisfactory results. An impulse-response is, however, not invariant, and changes with time depending on the room temperature and humidity, and the relative location between a sound source and a set of microphones. It is troublesome to measure an impulse response exactly each time. So, we have tried to cancel echoes using only one acoustic signal with echoes, obtained through a single microphone. In order to cancel echoes, we have to determine both delay times and amplitude ratios between direct sound and each of reflected sounds. Delay times are obtained as peaks of cepstrum of acoustic signal. Each amplitude ratio is iteratively searched so that resultant recovered sound may have the shortest duration. In the case that there are a few reflected signals, the result of experiment with reverberated signal synthesized using CD sound shows good recovery of an original sound.<<ETX>>\",\"PeriodicalId\":231484,\"journal\":{\"name\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1994.351841\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1994.351841","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在消除或抑制混响方面有许多研究。其中,预先测量室内脉冲响应的方法取得了非常满意的效果。然而,脉冲响应不是不变的,它会随着时间的变化而变化,这取决于房间的温度和湿度,以及声源和一组麦克风之间的相对位置。每次精确地测量脉冲响应是很麻烦的。因此,我们试图仅使用通过单个麦克风获得的具有回声的声学信号来消除回声。为了消除回声,我们必须确定直接声音和每个反射声音之间的延迟时间和振幅比。延迟时间作为声信号倒谱的峰值得到。每个振幅比迭代搜索,使最终恢复声音可能有最短的持续时间。在有少量反射信号的情况下,用CD声合成混响信号的实验结果表明,混响信号能很好地恢复原声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A fully passive echo-canceler using a single microphone
There are many studies on removal or suppression of reverberation. Among them, the approach, in which the impulse-response in a room is measured beforehand, has obtained very satisfactory results. An impulse-response is, however, not invariant, and changes with time depending on the room temperature and humidity, and the relative location between a sound source and a set of microphones. It is troublesome to measure an impulse response exactly each time. So, we have tried to cancel echoes using only one acoustic signal with echoes, obtained through a single microphone. In order to cancel echoes, we have to determine both delay times and amplitude ratios between direct sound and each of reflected sounds. Delay times are obtained as peaks of cepstrum of acoustic signal. Each amplitude ratio is iteratively searched so that resultant recovered sound may have the shortest duration. In the case that there are a few reflected signals, the result of experiment with reverberated signal synthesized using CD sound shows good recovery of an original sound.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Definition and analysis of an electronic device for synchronous circular sampling of locally periodic signals An optical instrumentation using dual sensor-dummy against noises Curvisensors for inside and outside robot arms A quartz crystal microbalance-type odor sensor using PVC-blended lipid membrane Locally mounted process gas analyzing system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1