肺肿瘤模拟模型用于经支气管微波热消融程序的可用性验证

L. Farina, G. Ruvio, M. O’halloran
{"title":"肺肿瘤模拟模型用于经支气管微波热消融程序的可用性验证","authors":"L. Farina, G. Ruvio, M. O’halloran","doi":"10.1109/comcas52219.2021.9628998","DOIUrl":null,"url":null,"abstract":"The introduction of lung navigation systems in the clinical practice has enabled a transbronchial minimally invasive access to flexible microwave ablation catheters for the treatment of lung cancer lesions. These complex procedures are currently performed under Cone-Beam CT and require lung navigation system and bronchoscope. On bench lung models integrating tumor-mimicking targets for usability assessment are in demand due to the lack of representative in vivo models. In this paper, three tumor models made of minced bovine muscle, bovine tripe and ovine heart were integrated inside inflated ovine lungs and assessed in terms of radiopacity, required piercing force and dielectric properties. The impact of iodine to enhance radiopacity in the other desired model characteristics is also evaluated.","PeriodicalId":354885,"journal":{"name":"2021 IEEE International Conference on Microwaves, Antennas, Communications and Electronic Systems (COMCAS)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Lung Tumor mimicking models for usability validation of transbronchial Microwave Thermal Ablation procedures\",\"authors\":\"L. Farina, G. Ruvio, M. O’halloran\",\"doi\":\"10.1109/comcas52219.2021.9628998\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The introduction of lung navigation systems in the clinical practice has enabled a transbronchial minimally invasive access to flexible microwave ablation catheters for the treatment of lung cancer lesions. These complex procedures are currently performed under Cone-Beam CT and require lung navigation system and bronchoscope. On bench lung models integrating tumor-mimicking targets for usability assessment are in demand due to the lack of representative in vivo models. In this paper, three tumor models made of minced bovine muscle, bovine tripe and ovine heart were integrated inside inflated ovine lungs and assessed in terms of radiopacity, required piercing force and dielectric properties. The impact of iodine to enhance radiopacity in the other desired model characteristics is also evaluated.\",\"PeriodicalId\":354885,\"journal\":{\"name\":\"2021 IEEE International Conference on Microwaves, Antennas, Communications and Electronic Systems (COMCAS)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE International Conference on Microwaves, Antennas, Communications and Electronic Systems (COMCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/comcas52219.2021.9628998\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on Microwaves, Antennas, Communications and Electronic Systems (COMCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/comcas52219.2021.9628998","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

肺导航系统在临床实践中的引入,使得经支气管微创使用柔性微波消融导管治疗肺癌病变成为可能。这些复杂的手术目前在锥形束CT下进行,需要肺部导航系统和支气管镜。由于缺乏具有代表性的体内模型,因此需要整合肿瘤模拟靶点的台式肺模型来进行可用性评估。本文将牛肉糜、牛肚和羊心脏三种肿瘤模型植入充气后的羊肺内,并对其放射不透性、所需穿刺力和介电性能进行评估。碘对增强其他所需模型特征的辐射不透明度的影响也进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lung Tumor mimicking models for usability validation of transbronchial Microwave Thermal Ablation procedures
The introduction of lung navigation systems in the clinical practice has enabled a transbronchial minimally invasive access to flexible microwave ablation catheters for the treatment of lung cancer lesions. These complex procedures are currently performed under Cone-Beam CT and require lung navigation system and bronchoscope. On bench lung models integrating tumor-mimicking targets for usability assessment are in demand due to the lack of representative in vivo models. In this paper, three tumor models made of minced bovine muscle, bovine tripe and ovine heart were integrated inside inflated ovine lungs and assessed in terms of radiopacity, required piercing force and dielectric properties. The impact of iodine to enhance radiopacity in the other desired model characteristics is also evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance Enhancement of Integrated Circuits and Power Devices via Embedded Diamond Heat Management A Balanced, Series Fed Horn Array Antenna Modeling and Analysis of Spatial Distributions of Users in Massive MIMO Systems Ultra-Wideband Transmission Lines on Complex Structures via Extendable Aerosol Jet 3D-Printing Recent Progress in Revision of IEEE Std 1720-2012 Recommended Practice for Near-Field Antenna Measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1