{"title":"基于tsv嵌入式微探针阵列的64通道无线神经传感微系统","authors":"Yu-Chieh Huang, Po-Tsang Huang, Yu-Chen Hu, Shang-Lin Wu, Y. You, Yung-Kuei Wang, J. Duann, Tzai-Wen Chiu, W. Hwang, Kuan-Neng Chen, C. Chuang, J. Chiou","doi":"10.1109/TRANSDUCERS.2017.7993979","DOIUrl":null,"url":null,"abstract":"To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.","PeriodicalId":174774,"journal":{"name":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 64-channel wireless neural sensing microsystem with TSV-embedded micro-probe array for neural signal acquisition\",\"authors\":\"Yu-Chieh Huang, Po-Tsang Huang, Yu-Chen Hu, Shang-Lin Wu, Y. You, Yung-Kuei Wang, J. Duann, Tzai-Wen Chiu, W. Hwang, Kuan-Neng Chen, C. Chuang, J. Chiou\",\"doi\":\"10.1109/TRANSDUCERS.2017.7993979\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.\",\"PeriodicalId\":174774,\"journal\":{\"name\":\"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2017.7993979\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2017.7993979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了提高高密度神经传感信号的信号完整性,本文提出了一种可植入的高空间分辨率μ探针阵列,采用透硅孔(TSV) 2.5D集成技术,实现了可植入器件在柔性印刷电路(FPC)介面上的小型化。该微系统由2个32通道神经传感芯片和1个用于神经信号处理的射频芯片组成。μ探针阵列采用基于伪电阻的模拟前端放大器构成的神经信号采集与处理电路,可以获得较好的信噪比。此外,在FPC的背面还实现了接收天线,用于无线数据和电力传输。所提出的μ探针阵列、Tx和Rx天线、32通道神经传感电路在64通道无线微系统中的可行性已经成功地证明了未来集成和动物实验的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A 64-channel wireless neural sensing microsystem with TSV-embedded micro-probe array for neural signal acquisition
To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Full integration of a dielectric elastomer actuator with a flexible 1 kV thin-film transistor Fully casted stretchable triboelectric device for energy harvesting and sensing made of elastomeric materials Local magnetization and sensing of flexible magnetic tag for long-term monitoring under wet environment Broadband frequency viscositymeasurement using low TCF shear mode resonators consisting of C-axis tilted scaln thin film on thick at-cut quartz plate Analysis of environmental bacteria at single-cell level
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1