Yu-Chieh Huang, Po-Tsang Huang, Yu-Chen Hu, Shang-Lin Wu, Y. You, Yung-Kuei Wang, J. Duann, Tzai-Wen Chiu, W. Hwang, Kuan-Neng Chen, C. Chuang, J. Chiou
{"title":"基于tsv嵌入式微探针阵列的64通道无线神经传感微系统","authors":"Yu-Chieh Huang, Po-Tsang Huang, Yu-Chen Hu, Shang-Lin Wu, Y. You, Yung-Kuei Wang, J. Duann, Tzai-Wen Chiu, W. Hwang, Kuan-Neng Chen, C. Chuang, J. Chiou","doi":"10.1109/TRANSDUCERS.2017.7993979","DOIUrl":null,"url":null,"abstract":"To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.","PeriodicalId":174774,"journal":{"name":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A 64-channel wireless neural sensing microsystem with TSV-embedded micro-probe array for neural signal acquisition\",\"authors\":\"Yu-Chieh Huang, Po-Tsang Huang, Yu-Chen Hu, Shang-Lin Wu, Y. You, Yung-Kuei Wang, J. Duann, Tzai-Wen Chiu, W. Hwang, Kuan-Neng Chen, C. Chuang, J. Chiou\",\"doi\":\"10.1109/TRANSDUCERS.2017.7993979\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.\",\"PeriodicalId\":174774,\"journal\":{\"name\":\"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2017.7993979\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2017.7993979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 64-channel wireless neural sensing microsystem with TSV-embedded micro-probe array for neural signal acquisition
To enhance the signal integrity of high-density neural-sensing signals, this work presents an implantable high spatial resolution μ-probe array with through-silicon via (TSV) 2.5D integration technology that realizes a miniaturized implantable device on flexible printed circuit (FPC) interposer. The proposed microsystem was composed of two 32-channel neural sensing chips and one radio frequency chip for neural signal processing. The μ-probe array can achieve better signal-to-noise ratio with neural-signal acquisition and processing circuit composed of a pseudo-resistor-based analog front-end amplifier. Moreover, a receiving antenna is also implemented on the backside of FPC for wireless data and power transmission. The feasibility of the proposed μ-probe array, Tx and Rx antenna, 32-channel neural sensing circuits in the 64-channel wireless microsystem have been successfully demonstrated for future integration and animal experiments.