提供不间断辅助服务的智能电网电源变流器控制算法

L. Piegari, P. Tricoli
{"title":"提供不间断辅助服务的智能电网电源变流器控制算法","authors":"L. Piegari, P. Tricoli","doi":"10.1109/ICHQP.2010.5625448","DOIUrl":null,"url":null,"abstract":"This paper deals with the use of grid-connected photovoltaic (PV) power plants for supplying the ancillary service of reactive power compensation to the distribution grid. A control strategy has been developed for controlling both real and reactive power exchanged with the distribution network. The paper suggests how the real and reactive power references should be selected in order to maximize the electrical energy generated by PV arrays and to exploit the apparent power of the inverter close to its rated value. The choice suggested for reference signals allows reactive power compensation service also when the solar irradiation is negligible. The control strategy is then applied to a sample grid-connected PV unit, which has been simulated in Simulink environment. Numerical simulations show that, using an adaptive Perturb & Observe algorithm, the maximum power point tracking is achieved in about 2 seconds, both at starting and when the irradiation changes. The inverter is also capable of giving without interruptions the reactive power support to the grid, reducing grid currents and voltage drops along the line respect to the classical configuration where no reactive compensation is present.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":"{\"title\":\"A control algorithm of power converters in smart-grids for providing uninterruptible ancillary services\",\"authors\":\"L. Piegari, P. Tricoli\",\"doi\":\"10.1109/ICHQP.2010.5625448\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with the use of grid-connected photovoltaic (PV) power plants for supplying the ancillary service of reactive power compensation to the distribution grid. A control strategy has been developed for controlling both real and reactive power exchanged with the distribution network. The paper suggests how the real and reactive power references should be selected in order to maximize the electrical energy generated by PV arrays and to exploit the apparent power of the inverter close to its rated value. The choice suggested for reference signals allows reactive power compensation service also when the solar irradiation is negligible. The control strategy is then applied to a sample grid-connected PV unit, which has been simulated in Simulink environment. Numerical simulations show that, using an adaptive Perturb & Observe algorithm, the maximum power point tracking is achieved in about 2 seconds, both at starting and when the irradiation changes. The inverter is also capable of giving without interruptions the reactive power support to the grid, reducing grid currents and voltage drops along the line respect to the classical configuration where no reactive compensation is present.\",\"PeriodicalId\":180078,\"journal\":{\"name\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2010.5625448\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

摘要

本文研究了利用并网光伏电站为配电网提供无功补偿的辅助服务。提出了一种同时控制与配电网交换的实功率和无功功率的控制策略。为了使光伏阵列产生的电能最大化,并使逆变器的视在功率接近额定值,本文提出了如何选择实功率基准和无功功率基准。当太阳辐照可以忽略不计时,参考信号的选择也允许无功补偿服务。并将该控制策略应用于一个光伏并网机组实例,在Simulink环境中进行了仿真。数值模拟表明,采用自适应Perturb & Observe算法,在启动和辐照变化时均可在约2秒内实现最大功率点跟踪。逆变器还能够在不中断的情况下向电网提供无功功率支持,相对于无功补偿的经典配置,减少电网电流和电压降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A control algorithm of power converters in smart-grids for providing uninterruptible ancillary services
This paper deals with the use of grid-connected photovoltaic (PV) power plants for supplying the ancillary service of reactive power compensation to the distribution grid. A control strategy has been developed for controlling both real and reactive power exchanged with the distribution network. The paper suggests how the real and reactive power references should be selected in order to maximize the electrical energy generated by PV arrays and to exploit the apparent power of the inverter close to its rated value. The choice suggested for reference signals allows reactive power compensation service also when the solar irradiation is negligible. The control strategy is then applied to a sample grid-connected PV unit, which has been simulated in Simulink environment. Numerical simulations show that, using an adaptive Perturb & Observe algorithm, the maximum power point tracking is achieved in about 2 seconds, both at starting and when the irradiation changes. The inverter is also capable of giving without interruptions the reactive power support to the grid, reducing grid currents and voltage drops along the line respect to the classical configuration where no reactive compensation is present.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonic domain modeling of transformer nonlinear characteristic with piece-wise approximation Classification of Power Quality disturbances using the iterative Hilbert Huang Transform The problems of centralized decrease of harmonic voltages in the HV networks with distributed nonlinear loads Elimination of harmonics using multi-pulse rectifiers Power quality in public lighting systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1