{"title":"基于运动的气管插管反馈系统","authors":"Ashley Sturgeon, Elie Sarraf, J. Moore","doi":"10.1115/dmd2022-1024","DOIUrl":null,"url":null,"abstract":"\n Endotracheal intubation is a common procedure that is performed for patients who are unable to adequately breathe. This procedure is often more successful when performed inside a hospital, but there are emergency situations that require out of hospital intubations. For both in-hospital and out of hospital, the statistics for flawed and failed intubation attempts are high. The primary risk associated with prolonged and failed intubation attempts are hypoxia leading to brain injury and death. To mitigate these risks, a motion-based feedback training system is proposed. Experimentation is performed to track the position of a laryngoscope during a manikin intubation. It was found that during intubation there was a significant range of motion in the x direction up to 120 and 114 mm. Also, it was found that for one trial the tortuosity value was significantly higher at 75. Overall results show that significant delicate movements are necessary, and that user movement varied between cases.","PeriodicalId":236105,"journal":{"name":"2022 Design of Medical Devices Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Motion Based Feedback System for Endotracheal Intubation\",\"authors\":\"Ashley Sturgeon, Elie Sarraf, J. Moore\",\"doi\":\"10.1115/dmd2022-1024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Endotracheal intubation is a common procedure that is performed for patients who are unable to adequately breathe. This procedure is often more successful when performed inside a hospital, but there are emergency situations that require out of hospital intubations. For both in-hospital and out of hospital, the statistics for flawed and failed intubation attempts are high. The primary risk associated with prolonged and failed intubation attempts are hypoxia leading to brain injury and death. To mitigate these risks, a motion-based feedback training system is proposed. Experimentation is performed to track the position of a laryngoscope during a manikin intubation. It was found that during intubation there was a significant range of motion in the x direction up to 120 and 114 mm. Also, it was found that for one trial the tortuosity value was significantly higher at 75. Overall results show that significant delicate movements are necessary, and that user movement varied between cases.\",\"PeriodicalId\":236105,\"journal\":{\"name\":\"2022 Design of Medical Devices Conference\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 Design of Medical Devices Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/dmd2022-1024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Design of Medical Devices Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2022-1024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

气管内插管是一种常见的手术,用于无法充分呼吸的患者。在医院内进行这种手术通常更成功,但也有紧急情况需要在医院外插管。无论是在医院内还是医院外,有缺陷和失败的插管尝试的统计数据都很高。长期插管失败的主要危险是缺氧导致脑损伤和死亡。为了降低这些风险,提出了一种基于动作的反馈训练系统。实验进行跟踪喉镜的位置在假人插管。我们发现,在插管期间,在x方向上有一个显著的运动范围,可达120和114毫米。此外,我们还发现,在一次试验中,弯曲度值显著高于75。总体结果表明,重要的精细动作是必要的,并且用户的动作在不同情况下有所不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Motion Based Feedback System for Endotracheal Intubation
Endotracheal intubation is a common procedure that is performed for patients who are unable to adequately breathe. This procedure is often more successful when performed inside a hospital, but there are emergency situations that require out of hospital intubations. For both in-hospital and out of hospital, the statistics for flawed and failed intubation attempts are high. The primary risk associated with prolonged and failed intubation attempts are hypoxia leading to brain injury and death. To mitigate these risks, a motion-based feedback training system is proposed. Experimentation is performed to track the position of a laryngoscope during a manikin intubation. It was found that during intubation there was a significant range of motion in the x direction up to 120 and 114 mm. Also, it was found that for one trial the tortuosity value was significantly higher at 75. Overall results show that significant delicate movements are necessary, and that user movement varied between cases.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Communicating Cybersecurity and Privacy Design Attributes through Privacy Labeling of Consumer Electronic Medical Devices A Novel Tool for Auricle Retraction During Closure of Post-Auricular Incisions Development and Characterization of Biostable Hydrogel Robotic Actuators for Implantable Devices: Tendon Actuated Gelatin Non-Invasive Diagnosis of Deep Vein Thrombosis to Expedite Treatment and Prevent Pulmonary Embolism During Gestation Development of an Epicardial Mapping Tank for Noninvasive Electrical Mapping of Ex Vivo Large Mammalian Hearts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1