用于估计施加在手术器械尖端的力的三自由度传感器

Suyong Kim, Cheongjun Kim, Suhwan Park, D. Lee
{"title":"用于估计施加在手术器械尖端的力的三自由度传感器","authors":"Suyong Kim, Cheongjun Kim, Suhwan Park, D. Lee","doi":"10.1109/ICAR.2017.8023509","DOIUrl":null,"url":null,"abstract":"Estimation of the force applied to the tip of a surgical instrument is necessary to render high-fidelity haptic feedback. Accuracy of the force estimation suffers from friction caused by the rubber packing inside the trocar. This paper proposes a 3-DOF force sensor installed to the trocar support. It is possible to estimate the 2-DOF radial force applied to the instrument tip and the 1-DOF axial friction occurring in the trocar by using the 3-DOF force sensor. Accuracy of the estimation, however, deteriorates due to the reaction moment that occurs at the trocar support. An I-shaped force sensor is designed to reduce coupling effect which is caused by the reaction moment. Design parameters of the sensor are optimized to minimize the coupling effect by using ANSYS software. The sensor is manufactured and calibrated using the least-square calibration method. L2 relative error of the estimation of the radial force applied to the instrument tip is less than 6.30 %. The axial reaction force corresponding to the friction is also estimated with relative error less than 8.63 %.","PeriodicalId":198633,"journal":{"name":"2017 18th International Conference on Advanced Robotics (ICAR)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A 3-DOF sensor to estimate the force applied to the tip of a surgical instrument\",\"authors\":\"Suyong Kim, Cheongjun Kim, Suhwan Park, D. Lee\",\"doi\":\"10.1109/ICAR.2017.8023509\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Estimation of the force applied to the tip of a surgical instrument is necessary to render high-fidelity haptic feedback. Accuracy of the force estimation suffers from friction caused by the rubber packing inside the trocar. This paper proposes a 3-DOF force sensor installed to the trocar support. It is possible to estimate the 2-DOF radial force applied to the instrument tip and the 1-DOF axial friction occurring in the trocar by using the 3-DOF force sensor. Accuracy of the estimation, however, deteriorates due to the reaction moment that occurs at the trocar support. An I-shaped force sensor is designed to reduce coupling effect which is caused by the reaction moment. Design parameters of the sensor are optimized to minimize the coupling effect by using ANSYS software. The sensor is manufactured and calibrated using the least-square calibration method. L2 relative error of the estimation of the radial force applied to the instrument tip is less than 6.30 %. The axial reaction force corresponding to the friction is also estimated with relative error less than 8.63 %.\",\"PeriodicalId\":198633,\"journal\":{\"name\":\"2017 18th International Conference on Advanced Robotics (ICAR)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 18th International Conference on Advanced Robotics (ICAR)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICAR.2017.8023509\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 18th International Conference on Advanced Robotics (ICAR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAR.2017.8023509","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

估计施加在手术器械尖端的力对于提供高保真的触觉反馈是必要的。力估计的准确性受到套管针内橡胶填料摩擦的影响。本文提出了一种安装在套管针支架上的三自由度力传感器。使用3-DOF力传感器,可以估计施加到仪器尖端的2-DOF径向力和套管针中发生的1-DOF轴向摩擦。然而,由于在套管针支撑处发生的反应力矩,估计的准确性会下降。设计了一种i型力传感器,以减小反作用力引起的耦合效应。利用ANSYS软件对传感器的设计参数进行优化,使耦合效应最小化。采用最小二乘校准法制造和校准传感器。仪器尖端径向力估计的L2相对误差小于6.30%。计算得到了摩擦作用下的轴向反作用力,相对误差小于8.63%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A 3-DOF sensor to estimate the force applied to the tip of a surgical instrument
Estimation of the force applied to the tip of a surgical instrument is necessary to render high-fidelity haptic feedback. Accuracy of the force estimation suffers from friction caused by the rubber packing inside the trocar. This paper proposes a 3-DOF force sensor installed to the trocar support. It is possible to estimate the 2-DOF radial force applied to the instrument tip and the 1-DOF axial friction occurring in the trocar by using the 3-DOF force sensor. Accuracy of the estimation, however, deteriorates due to the reaction moment that occurs at the trocar support. An I-shaped force sensor is designed to reduce coupling effect which is caused by the reaction moment. Design parameters of the sensor are optimized to minimize the coupling effect by using ANSYS software. The sensor is manufactured and calibrated using the least-square calibration method. L2 relative error of the estimation of the radial force applied to the instrument tip is less than 6.30 %. The axial reaction force corresponding to the friction is also estimated with relative error less than 8.63 %.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Questionnaire experiment using networked service robots Model selection for incremental learning of generalizable movement primitives Safety evaluation method of robot arm considering energy of contact Robotman: A security robot for human-robot interaction Physical edge detection in clothing items for robotic manipulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1