F. Qin, L. Lei, S. Xu, C. Li, D. Wang
{"title":"l波段全腔轴向提取相对论磁控管的实验研究","authors":"F. Qin, L. Lei, S. Xu, C. Li, D. Wang","doi":"10.1109/PPC.2017.8291163","DOIUrl":null,"url":null,"abstract":"Experimental results of an L band all cavity axial extraction relativistic magnetron (RM) working at 1.57 GHz is presented. In this 6-cavity RM configuration, microwave from two adjacent cavities is coupled into an axially oriented coaxial sector waveguide through radial slots on the cavities. This configuration is more compact because only three sector waveguides are added outside the magnetron cavity without increasing the radial dimension significantly. Simulation results reveal that this tube could generate a microwave power of 700 MW at the frequency of 1.57 GHz, corresponding to a power conversion efficiency of 50% when employing an electron beam of 350 kV and 4.0 kA. This tube is tested on a compact Marx generator in our lab. In experiment, this tube could generate a microwave power of over 500 MW at 1.57 GHz when employing guiding magnetic field of 0.22 T and input beam voltage of 345 kV and current of 4.8 kA, with a corresponding efficiency of about 30%. Experimental results reveal that this tube is a preferred configuration for a compact relativistic magnetron with relatively high power conversion efficiency.","PeriodicalId":247019,"journal":{"name":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental investigation of an l band all cavity axial extraction relativistic magnetron\",\"authors\":\"F. Qin, L. Lei, S. Xu, C. Li, D. Wang\",\"doi\":\"10.1109/PPC.2017.8291163\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experimental results of an L band all cavity axial extraction relativistic magnetron (RM) working at 1.57 GHz is presented. In this 6-cavity RM configuration, microwave from two adjacent cavities is coupled into an axially oriented coaxial sector waveguide through radial slots on the cavities. This configuration is more compact because only three sector waveguides are added outside the magnetron cavity without increasing the radial dimension significantly. Simulation results reveal that this tube could generate a microwave power of 700 MW at the frequency of 1.57 GHz, corresponding to a power conversion efficiency of 50% when employing an electron beam of 350 kV and 4.0 kA. This tube is tested on a compact Marx generator in our lab. In experiment, this tube could generate a microwave power of over 500 MW at 1.57 GHz when employing guiding magnetic field of 0.22 T and input beam voltage of 345 kV and current of 4.8 kA, with a corresponding efficiency of about 30%. Experimental results reveal that this tube is a preferred configuration for a compact relativistic magnetron with relatively high power conversion efficiency.\",\"PeriodicalId\":247019,\"journal\":{\"name\":\"2017 IEEE 21st International Conference on Pulsed Power (PPC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE 21st International Conference on Pulsed Power (PPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.2017.8291163\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2017.8291163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了工作频率为1.57 GHz的L波段全腔轴向提取相对论磁控管的实验结果。在这种6腔RM配置中,来自两个相邻腔的微波通过腔上的径向槽耦合到一个轴向同轴扇形波导中。这种结构更加紧凑,因为在磁控管腔外只添加了三个扇形波导,而不会显著增加径向尺寸。仿真结果表明,该管在1.57 GHz频率下可产生700 MW的微波功率,在350 kV、4.0 kA的电子束下,功率转换效率可达50%。该管在我们实验室的小型马克思发生器上进行了测试。在实验中,该管在0.22 T的引导磁场、345 kV的输入波束电压、4.8 kA的输入电流条件下,在1.57 GHz下可产生500 MW以上的微波功率,效率约为30%。实验结果表明,该管是紧凑型相对论磁控管的首选结构,具有较高的功率转换效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental investigation of an l band all cavity axial extraction relativistic magnetron
Experimental results of an L band all cavity axial extraction relativistic magnetron (RM) working at 1.57 GHz is presented. In this 6-cavity RM configuration, microwave from two adjacent cavities is coupled into an axially oriented coaxial sector waveguide through radial slots on the cavities. This configuration is more compact because only three sector waveguides are added outside the magnetron cavity without increasing the radial dimension significantly. Simulation results reveal that this tube could generate a microwave power of 700 MW at the frequency of 1.57 GHz, corresponding to a power conversion efficiency of 50% when employing an electron beam of 350 kV and 4.0 kA. This tube is tested on a compact Marx generator in our lab. In experiment, this tube could generate a microwave power of over 500 MW at 1.57 GHz when employing guiding magnetic field of 0.22 T and input beam voltage of 345 kV and current of 4.8 kA, with a corresponding efficiency of about 30%. Experimental results reveal that this tube is a preferred configuration for a compact relativistic magnetron with relatively high power conversion efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Pre-determination of partial discharge inception voltage in power cables using electrode gaps in air under AC voltage Modeling Marx generators for maximum pulse repetition rate estimation Triggering strategy of railgun power supply for the accurate control of the armature muzzle velocity Time-resolved measurements of Cygnus x-ray production using Aerogel Cherenkov Detector Analysis of nonlinear gyromagnetic line operation using LLG equation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1