{"title":"区域麻醉连续监测的光容积脉搏波成像算法","authors":"U. Rubins, J. Spigulis, A. Miscuks","doi":"10.1145/2993452.2994308","DOIUrl":null,"url":null,"abstract":"An efficient photoplethysmography imaging system and advanced algorithm for continuous monitoring of skin microcirculation was developed. The system comprises compact device and computer with software for visualizing of skin blood volume changes. The software is able to process high-resolution microcirculation amplitude maps in real-time. It was tested in clinical environment during the regional anesthesia procedures. The Eulerian-based method showed improved sensitivity and higher resolution of microcirculation maps.","PeriodicalId":198459,"journal":{"name":"2016 14th ACM/IEEE Symposium on Embedded Systems For Real-time Multimedia (ESTIMedia)","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Photoplethysmography imaging algorithm for continuous monitoring of regional anesthesia\",\"authors\":\"U. Rubins, J. Spigulis, A. Miscuks\",\"doi\":\"10.1145/2993452.2994308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An efficient photoplethysmography imaging system and advanced algorithm for continuous monitoring of skin microcirculation was developed. The system comprises compact device and computer with software for visualizing of skin blood volume changes. The software is able to process high-resolution microcirculation amplitude maps in real-time. It was tested in clinical environment during the regional anesthesia procedures. The Eulerian-based method showed improved sensitivity and higher resolution of microcirculation maps.\",\"PeriodicalId\":198459,\"journal\":{\"name\":\"2016 14th ACM/IEEE Symposium on Embedded Systems For Real-time Multimedia (ESTIMedia)\",\"volume\":\"11 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 14th ACM/IEEE Symposium on Embedded Systems For Real-time Multimedia (ESTIMedia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2993452.2994308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 14th ACM/IEEE Symposium on Embedded Systems For Real-time Multimedia (ESTIMedia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2993452.2994308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Photoplethysmography imaging algorithm for continuous monitoring of regional anesthesia
An efficient photoplethysmography imaging system and advanced algorithm for continuous monitoring of skin microcirculation was developed. The system comprises compact device and computer with software for visualizing of skin blood volume changes. The software is able to process high-resolution microcirculation amplitude maps in real-time. It was tested in clinical environment during the regional anesthesia procedures. The Eulerian-based method showed improved sensitivity and higher resolution of microcirculation maps.