排风温度对降低新建住宅室内空气污染物的影响

Seung-Rim Lee, SugnWon Cho, Ji-Ho Yoo, G. Cho
{"title":"排风温度对降低新建住宅室内空气污染物的影响","authors":"Seung-Rim Lee, SugnWon Cho, Ji-Ho Yoo, G. Cho","doi":"10.7836/kses.2022.42.1.077","DOIUrl":null,"url":null,"abstract":"In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.","PeriodicalId":276437,"journal":{"name":"Journal of the Korean Solar Energy Society","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of Flush-out Air Temperature on Reducing Indoor Air Pollutants in Newly Built Residential Buildings\",\"authors\":\"Seung-Rim Lee, SugnWon Cho, Ji-Ho Yoo, G. Cho\",\"doi\":\"10.7836/kses.2022.42.1.077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.\",\"PeriodicalId\":276437,\"journal\":{\"name\":\"Journal of the Korean Solar Energy Society\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Solar Energy Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7836/kses.2022.42.1.077\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Solar Energy Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7836/kses.2022.42.1.077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本研究中,研究了冲出温度对室内污染物减少的影响,其设计类似于住宅建筑的热环境室。将本研究结果与以往的研究结果进行比较。测量在11°C和16°C下进行,在。结果表明,与以往的研究结果相比,污染物减少了56% ~ 78%。即使在低温条件下,冲出也有减少污染物的作用。与现场实测结果比较,出水温度对污染物的减少效果不同;然而,经证实,即使在低温下,冲洗也有一定的减少污染物的效果。将本研究结果与前人野外和室内实验结果进行t检验比较,p值大于等于0.05,表明整个数据集中温度诱导通风次数不是影响污染物减排效果的显著因素。因此,根据温度对污染物减排效果的t检验分析结果,确认温度越高,污染物减排效果越大,为13% ~ 80%。温度对不同污染物的减排效果不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of Flush-out Air Temperature on Reducing Indoor Air Pollutants in Newly Built Residential Buildings
In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of Plenum Load on Cooling Capacity Design of Ceiling Radiant Cooling Panels Analysis of the Effect on Wake Decay Constant of Jensen Wake Model in a Wind Farm Design and Feasibility Study of a Real-Time Controlled Kinetic Facade System for Natural Lighting and Ventilation Comparing the Performance of Dimensional Reduction and Model Prediction Performance Due to Missing Data Handling for Building Energy Data Analysis Current Status of Green Remodeling Project and ECO2-OD: A Study on the Comparison of Characteristics by Buildings Using the Program
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1